Abstract
In this paper, exergy analysis of a 210 MW SPP (Steam Power Plant) is performed. Firstly, the plant is modeled and validated, followed by a parametric study to show the effects of various operating parameters on the performance parameters. The net power output, energy efficiency, and exergy efficiency are taken as the performance parameters, while the condenser pressure, main steam pressure, bled steam pressures, main steam temperature, and reheat steam temperature isnominated as the operating parameters. Moreover, multiple polynomial regression models are developed to correlate each performance parameter with the operating parameters. The performance is then optimizedby using Direct-searchmethod. According to the results, the net power output, energy efficiency, and exergy efficiency are calculated as 186.5 MW, 31.37 and 30.41%, respectively under normal operating conditions as a base case. The condenser is a major contributor towards the energy loss, followed by the boiler, whereas the highest irreversibilities occur in the boiler and turbine. According to the parametric study, variation in the operating parameters greatly influences the performance parameters. The regression models have appeared to be a good estimator of the performance parameters. The optimum net power output, energy efficiency and exergy efficiency are obtained as 227.6 MW, 37.4 and 36.4, respectively, which have been calculated along with optimal values of selected operating parameters.
Authors and Affiliations
Muhib Ali Rajper, Abdul Ghafoor Memon, Khanji Harijan
Integrated GIS-Based Site Selection of Hillside Development for Future Growth of Urban Areas
Urbanization is a challenging issue for developing countries, like Malaysia. Penang Island is one of the states of Malaysia selected as a study area where limited flat land exists. As a result, this would create urban en...
Conjugated Conduction-Free Convection Heat Transfer in an Annulus Heated at Either Constant Wall Temperature or Constant Heat Flux
In this paper, we investigate numerically the effect of thermal boundary conditions on conjugated conduction-free convection heat transfer in an annulus between two concentric cylinders using Fourier Spectral method. The...
Mobile Application Testing in Pakistan: A Survey
Research regarding MAT (Mobile Application Testing) in Pakistan is hard to discover and to the best of our knowledge, no work has been done in surveying MAT in Pakistan. In this work, we have examined the current trend a...
Semantic Based Cluster Content Discovery in Description First Clustering Algorithm
In the field of data analytics grouping of like documents in textual data is a serious problem. A lot of work has been done in this field and many algorithms have purposed. One of them is a category of algorithms which f...
Design and Performance of Broadband Dual Layer Circular Polarizer Based on Frequency Selective Surface for X-Band Applications
A dual-layer circular polarizer based on FSS (Frequency Selective Surface) composed of two periodic strips in xoy plane. The transmission characteristic of present structure is comprehensively investigated that convert l...