Experimental Behavior of Full Encased Composite Column under Axial Compression

Abstract

This paper presents the experimental behaviour of full encased composite columns (FECC) under axial compression. A composite column is a column in which steel section is embedded into concrete with longitudinal reinforcement as well as lateral reinforcement. In this papers results of full encased composite columns were compared with the conventional reinforced concrete columns and are presented in the form of graphs and tables. From the experimental results it was concluded that FECC can replace conventional reinforced concrete column when subjected to high compressive loads. Failure mode of both FECC and conventional reinforced concrete column were almost same.

Authors and Affiliations

Sagar Patil, Dr. Suresh Parekar

Keywords

Related Articles

Influence of Supplementary Materials on Properties of Concrete – A Review

A well-maintained infrastructure is a fundamental necessity for a modern society that provides great value, but ensuring that it meets all the requirements is challenging. Concrete as a construction material is in use f...

Design Optimization and Analysis of Shear Wall in High Rise Buildings Using ETABS

The shear wall is a structural element which is used to resist earthquake forces. These wall will consumptives shear forces & will prevent changing location-position of construction & consequently destruction. On other...

Causes of Coupling Failures and Preventive Actions

Couplings are critical parts of any transmission system, providing the smooth transmission of power from drive to driven equipment. If properly designed, selected and maintained, the coupling can last long and give sati...

Contribution of Foreign Direct Investment in India: Its Growth and Issues

Foreign Direct Investment acts as a bridge to fulfill the gap between investment and saving. In the process of economic development foreign capital helps to cover the domestic saving constraint and provide access to the...

Analyzing the Data in Hospital

Analyzing of the data in hospital is a managing system that helps doctors as well as the patient by providing options of booking appointments as per the convenience of both doctor and patients with the motive of medical...

Download PDF file
  • EP ID EP23044
  • DOI -
  • Views 251
  • Downloads 4

How To Cite

Sagar Patil, Dr. Suresh Parekar (2017). Experimental Behavior of Full Encased Composite Column under Axial Compression. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 5(1), -. https://europub.co.uk./articles/-A-23044