Factors That Impact Evaluation of Left Ventricular Systolic Parameters in Myocardial Perfusion Gated SPECT with 16 Frame and 8 Frame Acquisition Models
Journal Title: Molecular Imaging and Radionuclide Therapy - Year 2018, Vol 27, Issue 2
Abstract
Objective: Evaluating the effects of heart cavity volume, presence and absence of perfusion defect, gender and type of study (stress and rest) on the difference of systolic parameters of myocardial perfusion scan in 16 and 8 framing gated SPECT imaging. Methods: Cardiac gated SPECT in both 16 and 8 framing simultaneously and both stress and rest phases at one-day protocol was performed for 50 patients. Data have been reconstructed by filter back projection (FBP) method and left ventricular (LV) systolic parameters were calculated by using QGS software. The effect of some factors such as LV cavity volume, presence and absence of perfusion defect, gender and type of study on data difference between 8 and 16 frames were evaluated. Results: The differences in ejection fraction (EF), end-diastolic volume (EDV) and end-systolic volume (ESV) in both stress and rest were statistically significant. Difference in both framing was more in stress for EF and ESV, and was more in rest for EDV. Study type had a significant effect on differences in systolic parameters while gender had a significant effect on differences in EF and ESV in rest between both framings. Conclusion: In conclusion, results of this study revealed that difference of both 16 and 8 frames data in systolic phase were statistically significant and it seems that because of better efficiency of 16 frames, it cannot be replaced by 8 frames. Further well-designed studies are required to verify these findings.
Authors and Affiliations
Mojtaba Ansari, Hoda Hashemi, Mehdi Soltanshahi, Mohsen Qutbi, Zahra Azizmohammadi, Faraj Tabeie, Hamid Javadi, Esmail Jafari, Maryam Barekat, Majid Assadi
Giant Abdominal Aortic Aneurysm in Bone Scan
Abdominal aortic aneurysm (AAA) may be incidentally detected in three-phased bone scintigraphy. AAA should be diagnosed prior to the development of symptoms to perform elective repair surgery. We present a rare case who...
Super Scan Caused by Parathyroid Carcinoma Observed Both in 18F-FDG PET/CT Scan and Tc-99m MDP Bone Scintigraphy
Super scan is a well-known finding described in skeletal scintigraphy characterized by uniform symmetrically increased radiopharmaceutical uptake by bones and consequently diminished renal parenchymal activity. Sy et al....
18F-FDG-PET/CT in Initiation and Progression of Inflammation and Infection
Objective: Detection/localization of infection and inflammation is important for the initiation of correct treatment as well as its maintenance. Nuclear medicine imaging methods play an important role in determining infe...
Usefulness of 18F-FDG PET/CT in Cutaneous Melanoma Patients with Negative Sentinel Lymph Nodes and High Clark Levels
Objective: We investigated the utility of PET/CT in cutaneous melanoma (CM) patients with pathological negative sentinel lymph nodes (SLN), within the first year. Methods: The results of PET/CTs and SLN biopsy (SLNB) in...
Contribution of 18F-FDG PET/CT to Staging of Head and Neck Malignancies
Objectives: Accurate staging of head and neck cancer (HNC) plays an important role in patient management as well as protection of functional characteristics of the head and neck region. Our aim was to investigate the con...