Failure Study of Reinforced Concrete Buildings of Kathmandu Valley In Gorkha Earthquake 2015

Abstract

Nepal lies in earthquake prone zone. There are different fault zones in Nepal. Active fault of in this region causes several earthquakes in Nepal. In the recent, an earthquake of M7.8 occurred in 77 km NW of Kathmandu (in the boarder of Gorkha and Lam Jung) at 11:56 on 25 April 2015 with shallow depth of 15 km with maximum Mercalli Intensity of IX, lasting approximately thirty seconds. Nepal faced continued aftershocks throughout the country at the intervals of 15–20 minutes, with one shock reaching a magnitude of 6.7 on 26 April at 12:54:08. And another major earthquake of 7.3 (as per USGS report) occurred in 18 km south-east of Kodari and epicenter is in boarder of Dolkha and Sindhu pal chowk district at 12.51 on 12 May 2015. This article is concentrated to study of damages of reinforced concrete buildings only which are in Kathmandu valley in Gorkha Earthquake 2015. Effect of earthquake in reinforced concrete frame structures in Kathmandu valley are considered. Height of buildings is taken from two storied to ten storied. In this study it is discussed about the types of failures of reinforced concrete structures, observations and causes of structural failures, tilting of building, fully collapsed buildings, sandwich type failure of buildings, soft story failure of buildings, column failures, crushing of concrete failure of column, shear and bending failure of columns, shear failure of beams and beam-column joint failure, failure due to reinforcement deficiency, poor quality of concrete and infill wall failure. It is found that soil exploration in building site is not done in most of the failed building area so foundation failure in excessive settlement and tilting are observed, Configuration of buildings are not regular. It is observed the lack of structural design and not properly structural designed of buildings. In addition to this it is found that not proper reinforcement detailing of building elements and lack of quality control of construction materials. So, it is recommended that in the stage of soil exploration, planning, design and supervision of buildings, building norms should be strictly fulfilled. Technical expertise should be used in all process of work.

Authors and Affiliations

Dr Rajan Suwal

Keywords

Related Articles

Failure Study of Reinforced Concrete Buildings of Kathmandu Valley In Gorkha Earthquake 2015

Nepal lies in earthquake prone zone. There are different fault zones in Nepal. Active fault of in this region causes several earthquakes in Nepal. In the recent, an earthquake of M7.8 occurred in 77 km NW of Kathmandu (i...

IoT based Environmental Monitoring and Control System

IoT plays a major role in collecting the information from the sensing unit enclosing our environment due to alterations in the climate which led to the significance of environmental monitoring. This Paper presents a deve...

Reverse Innovation in Ayurveda: Lessons to Learn

Ayurveda has existed as a system of medicine in India since times immemorial. Earliest references to it are made in the ancient religious scriptures called Vedas dated more than 5000 years ago. The cross-country trade am...

Smart Waste Management System Using Sensor Technology

In this paper, we present the smartbin that transform the waste management system taking a step towards clean public places. The mechanism developed comprises of Arduino Microcontroller used to interface with the three u...

Design and Simulation Analysis of Sliding Mode Controller for DC-DC Cuk Converter

Due to compact size and fast dynamic response DC-DC converters are used to a great extent. DC-DC Cuk converter has switching transients which leads to switching losses and harmonics generation. With a linear controller l...

Download PDF file
  • EP ID EP408393
  • DOI -
  • Views 145
  • Downloads 0

How To Cite

Dr Rajan Suwal (2018). Failure Study of Reinforced Concrete Buildings of Kathmandu Valley In Gorkha Earthquake 2015. International Journal of Modern Research In Engineering & Management., 1(5), 22-32. https://europub.co.uk./articles/-A-408393