Fault Analysis Using Superconducting Fault Current Limiters

Abstract

Smart grid is an advancement of the existing electrical grid. The key feature of the future smart grid is the decentralization of the main power grid into number of smaller grids (known as micro grids). Interconnection of the distributed generating (DG) sources is required with the existing electrical grid to enhance the reliability of the power system. Extensive integration of DG sources within a smart grid causes failure of a successful implementation of smart grid due to the presence of enormous fault current. Superconducting Fault Current Limiter (SFCL) has the capability to reduce the fault current level within the first cycle of the fault current resulting in an increased transient stability of the power system. In this paper an application of a resistive type SFCL, designed in Simulink / SimPower System has been proposed to limit the fault current that occurs in an interconnected power system. A resistive type SFCL model has been developed in Simulink and the performance of SFCL at different locations has been analysed in the proposed system considering wind farm (10 MVA) as a distributed generating (DG) source with the conventional power plant, to reduce the fault current in micro grids. The feasible location of the SFCL having no negative effect on the DG source has been evaluated in three phase and single line to ground faults at various positions in the smart grid.

Authors and Affiliations

Sneha Rai, Dr. Pankaj Rai

Keywords

Related Articles

Quantitative evaluation and analysis of morphometric parameters derived from ASTER DEM using ARC Hydro tool in a GIS Environment – A study of Vaishali River Basin of Madhya Pradesh

GIS has become a key source to understand the hydrological conditions of watersheds for the last few decades. Arc Hydro tool of ArcGIS has been proven its role in the automated extraction of drainage network and morphome...

Performance Study of Silicone Rubber Polymer was Filled Fly Ash as Insulator Material on High Voltage Transmission Tower

Silicone rubber has emerged as an alternative material for porcelain insulators and glass insulators on a high voltage transmission because it is lightweight, so it helps in planning the structure of the transmission tow...

Fully Automated Electronic Mock Examination in an Introductory Computer Science Course

A mock examination is an exam that does not count for credit. It is taken before an official examination and gives students the opportunity to practice for the later, important exam. The mock examination provides student...

Implementation of Analytic Network Process Method for Decision Support System on Library Services Quality Assurance Based on ISO 9001

This research proposes a model that combines Quality Management System (QMS) ISO 9001:2015 approach and Analytic Network Process method. Implementation of QMS is required to provide services oriented on customer needs th...

Facial Expression Recognition Using Local Binary Pattern and Support Vector Machine

Facial expression analysis is a remarkable and demanding problem, and impacts significant applications in various fields like human-computer interaction and data-driven animation. Developing an efficient facial represent...

Download PDF file
  • EP ID EP180347
  • DOI -
  • Views 208
  • Downloads 0

How To Cite

Sneha Rai, Dr. Pankaj Rai (2016). Fault Analysis Using Superconducting Fault Current Limiters. International Journal of Innovative Research in Advanced Engineering, 0(0), 72-80. https://europub.co.uk./articles/-A-180347