Fluid Flow Analysis of Jacket Cooling System for Marine Diesel Engine 93 Kw

Abstract

The main function of cooling system is to control the temperature in the engine. To know the flow in the jacket cooling system for marine diesel engine 93 KW and the couple simulation between 1D modeling and 3D modeling, the methodology used. The analysis process was performed by using 3 different software. The methodology to analysis fluid flow is CFD (computational fluid dynamic) with steps were problem identification, literature study, design the jacket cooling system based on the cummin diesel engine 93 KW, 1D modeling of cooling system, 3D modeling fluid flow in jacket cooling system, and conclusion. The input of 3D jacket cooling simulation are mass flow, fluid temperature, wall temperature, and heat transfer. The result from this bachelor thesis is fluid flow in jacket cooling system and another parameter output such as temperature flow and velocity if fluid in the jacket cooling system. The result of the flow in jacket cooling is much turbulance in various are of jacket cooling its mean the jacket cooling have a good efficiency of heat transfer, and the fluid temperature show the increasing temperature from inlet to outlet because of heat transfer happen in the jacket cooling between wall of jacket cooling and fluid. The engine speed will affect the cooling system, if the engine speed is increasing, the speed of flow will increase because the cylinder block need more coolant and the temperature of cylinder block will increase

Authors and Affiliations

Aguk Zuhdi Muhammad Fathallah, Wolfgang Busse, Fadhil Rizki Clausthaldi

Keywords

Related Articles

Analysis of Engine Propeller Matching of DC Motor as a Main Propulsion

The development of ship always searches through the most benefits system for reducing costs of propulsion system without increase pollution. Diesel propulsion system or also known as conventional propulsion system is eff...

Design of Protection Coordination for Overcurrent on Electrical System in Tanker Ship Plan Using Electro Mechanical Trip Device

Disturbance of power system in ship is unavoidable case that required a function from safety system to separate the affected parts of system. The disturbance in electrical system generally is a short-circuit current. It...

Analysis Of Stress Distribution Connection System To Knock Down River Ferry

Musi river is a wide and very long river used by local citizen for the fro. Water transportation remains the choice of local citizen though other infrastructure was built. Hence today, water transportation remains best c...

Technical Analysis of Kort Nozzle Application for SPOB Ship 4990 DWT on River

Propeller is a locomotor shaped vanes are used to drive ships, and also propellers which serves to move tehaga by changing the turning force of the propeller thrust menggerakakan into the vessel. In increasing the value...

Development of Load Characteristic for The Main Engine and Its PLC Compatible Preparation in Cooperation with The Water Brake as The Generator

Water brake can be used in any application where a load brake is required on a rotational load. In the engine industry, dynamometer is used in conjunction with a power source and instrumentation to determine engine HP, T...

Download PDF file
  • EP ID EP220064
  • DOI 10.12962/j25481479.v1i2.2028
  • Views 434
  • Downloads 0

How To Cite

Aguk Zuhdi Muhammad Fathallah, Wolfgang Busse, Fadhil Rizki Clausthaldi (2017). Fluid Flow Analysis of Jacket Cooling System for Marine Diesel Engine 93 Kw. International Journal of Marine Engineering Innovation and Research, 1(2), 39-45. https://europub.co.uk./articles/-A-220064