Follow-up CT-Scan after TEVAR: is possible to prevent potential catastrophic complications?

Journal Title: Advancements in Cardiovascular Research - Year 2018, Vol 1, Issue 1

Abstract

Thoracic endovascular aortic repair (TEVAR) is considered a safe and feasible technique especially in complex cases. One of the most catastrophic complications during follow up is modular disconnection. When modular disconnection occurs, end leak is massive and risk of mortality is dramatically increased. We report our findings during follow up of a 49 years male underwent ascending aorta replacement for acute Type A aortic dissection and subsequently surgical replacement of aortic arch and TEVAR due to huge enlargement of the thoraco-abdominal false lumen. Our analysis suggest.com more attention on topographic changes of the prostheses to prevent this fatal complicationsThoracic endovascular aortic repair (TEVAR) is considered a safe and feasible technique also in complex cases with a lower morbidity and mortality rates when compared with open repair. However, follow-up CT-Scan is recommended periodically, at 6-12 months, especially when an end leak of any type has been detected. Although not frequent, modular disconnection might occur and results in one of the most catastrophic complications. In long-term follow-up studies the aneurysm sac size and native aortic morphology have been found to increase the risk for modular disconnection [1]. In the Talent Thoracic Retrospective Registry, Fattori and Co-workers reported an occurrence of modular disconnection of 1.4% [2]. In Figure 1 we found a modular disconnection in an asymptomatic 49 years old man patient during his regular follow-up CT-Scan after TEVAR. The patient underwent ascending aorta replacement for acute Type A aortic dissection five years earlier. Due to huge enlargement of the thoraces-abdominal false lumen an additional surgical treatment for the replacement of aortic arch was needed 2 years later and was achieved by means of the E-Vita Open stent-graft prosthesis Jotec Inc, Hechingen, Germany. To complete the repair, few months after aortic arch replacement, two endovascular prostheses type Relay (Bolton Medical Inc., Sunrise, FL, USA) were placed to cover the distal thoracic and abdominal aorta; stenting of superior mesenteric artery was achieved by chimney technique.

Authors and Affiliations

Saitto Guglielmo, Zeitani Jacob

Keywords

Related Articles

Sleep Quality Disturbances and Blood Pressure Values

The aim of the study was to find out whether early blood pressure (TK) values in patients with fixed and medically treated hypertension correlated with sleep quality during the previous night, and that treatment with ril...

HTLV-1 Seropositivity and Unexplained Dilated Cardiomyopathy in Jamaican Patient

Background: Viruses have been implicated in the aetiology/pathogensis of unexplained dilated cardiomyopathy. 6% of adult Jamaicans are HTLV-1 seropositive. We therefore explored the relationship between HTLV-1 infectious...

Understanding the Demographic and Clinical Characteristics of Heart Failure to Improve Management Practices: The Caribbean Perspective

Heart Failure is a worldwide burden. The prevalence, incidence, mortality and morbidity rates reported show geographic variations, depending on the different aetiologies and clinical characteristics observed among patien...

The Comparison between Two Sternum Closure Techniques after Coronary Bypass Surgery; Sterna-BandĀ® (Peninsula) and Sternum Band (EthiconĀ®)

Introduction: Recovery failures such as sternal dehiscence, sternal pain, sternal wound infections, osteomyelit and mediastinit can be seen after median sternotomy in coroner bypass surgery. In this study, two sternum ba...

Follow-up CT-Scan after TEVAR: is possible to prevent potential catastrophic complications?

Thoracic endovascular aortic repair (TEVAR) is considered a safe and feasible technique especially in complex cases. One of the most catastrophic complications during follow up is modular disconnection. When modular disc...

Download PDF file
  • EP ID EP586121
  • DOI 10.32474/ACR.2018.01.000104
  • Views 75
  • Downloads 0

How To Cite

Saitto Guglielmo, Zeitani Jacob (2018). Follow-up CT-Scan after TEVAR: is possible to prevent potential catastrophic complications?. Advancements in Cardiovascular Research, 1(1), 10-12. https://europub.co.uk./articles/-A-586121