Force generation by orthodontic samarium cobalt and neodymium iron boron magnets at various distances-an Invitro study.
Journal Title: International Journal of Dental Science and Innovative Research (IJDSIR) - Year 2019, Vol 2, Issue 3
Abstract
AIM: To evaluate and compare the attractive and repulsive force values in Neodymium iron boron and Samarium cobalt magnets of different sizes at various distances. Materials and Methods: 168 cylindrical magnets each of neodymium iron boron and Samarium cobalt were procured and were grouped as Group I and Group II and further subdivided into A, B and C for 10x3mm, 6x3mm and 4x4mm sizes respectively. The force of attraction and repulsion was measured using the Instron Universal testing Machine. Results: The force was measured at nine specified distances and the readings obtained were statistically analysed using unpaired t test. Both the magnets of 4x4mm size when subjected to attraction and repulsive force at 10mm to 20mm distance apart could not generate any force suggesting lacking in ability to generate any force at that distance and above. Conclusion: The study showed that Neodymium iron boron magnets had higher force values for both attraction and repulsion for all the sizes ranging from 943.01-24.13gms.Samarium cobalt magnets had also generated significant force value ranging from 738-11.39gms for both attraction and repulsion. All the force values produced by these magnets can be used for orthodontic treatment either for orthopaedic correction or orthodontic tooth movement.
Authors and Affiliations
Eunice John
Peripheral Desmoplastic Ameloblastoma: Case Report And Review of Literature.
Sixty-seven percent of peripheral odontogenic tumors are ameloblastoma, however, among all ameloblastomas, the peripheral variant accounts to 2 – 10 %. Peripheral desmoplastic ameloblastoma is extremely rare variant of b...
Comparative Evaluation of Shade Matching of Vital Maxillary Central Incisor by Different Observers, Shade Guides and Instrument.
Objectives: This study tested the hypothesis that the agreement between observer visual dental shade matches and instrumental shade identification is higher using the Vita 3DMaster ® (3D) shade guide than the Vita classi...
Nager Acrofacial Dysostosis: A Case Report.
Nager syndrome is a genetic condition which causes a myriad of oro-facial and limb manifestations. Knowledge about the various clinical symptoms is essential to a pediatric dentist to provide proper dental care for the p...
Biomechanical Stress Analysis of Mandibular First Permanent Molar Restored with Different Restorative Materials : A 3-Dimensional Finite Element Analysis.
Normal mastication with its varying magnitude and direction generates extensive intransigent stresses in teeth and their supporting tissues. The structure of the human tooth and its supporting tissues is a multifarious a...
Efficacy of Platelet Rich Fibrin as a graft and membrane Vs Hyaluronic acid and Amniotic membrane in the treatment of Grade II mandibular furcation defects: A Randomized Clinical Trial.
Context: Furcations of multirooted teeth are very challenging to treat, as their anatomy is complex. Mandibular furcations are more conducive to treatment. Previous studies validated employing graft and membrane to be be...