FREQUENCY INDEXES OF RESPIRATION DURING INTERRUPTER EXPERIMENT

Journal Title: Metrology and Measurement Systems - Year 2008, Vol 15, Issue 2

Abstract

A new issue of the respiratory mechanics evaluation by the frequency mode of the interrupter technique is undertaken in the paper. The aim of the computer-aided research is to show the abilities to separate airways and tissue properties of the respiratory system. The proposed evaluation procedure of the identification quality in the modified DuBois model proves the possibility to conduct repeatable measurements of the important diagnostic indexes. The obtained precision of the parametric description of the investigated physiological system suggests the need to continue the work in the outlined direction. Their final effect can be a portable device with applicability to clinically diffcult subjects - infants and pre-school children.

Authors and Affiliations

IRENEUSZ JABŁOŃSKI, ANUSZ MROCZKA

Keywords

Related Articles

THE DEPENDENCE OF BRASS HARDNESS MEASUREMENT SYSTEM ON TIME

Measurement system analysis (MSA) was used for estimation of hardness (HBS) measure- ment system capability. The time dependence of capability was evaluated. Experimental material Cu-Zn-Al cast alloy was used as shape me...

APPLICATION OF A BAYESIAN ESTIMATOR FOR IDENTIFICATION OF EDIBLE OILS ON THE BASIS OF SPECTROPHOTOMETRIC DATA

Spectrophotometric analysis of oil mixtures, containing olive oil, is the subject of this paper. Its objective is to compare a new Bayesian estimator with the constrained least-squares estimator, when applied for estimat...

PARTICULARITIES OF THE CYCLIC A/D CONVERTERS ENOB DEFINITION AND MEASUREMENT

The paper is devoted to the methods of accurate assessment and analysis of the expected and actual effective number of bits (ENOB) of cyclic analog-to-digital converters. The equivalence of definition of ENOB in the IEEE...

FACTORS LIMITING EXTREMELY SENSITIVE MEASURING RANGES OF CONTEMPORARY PICOAMMETERS<br />

In the paper the principle of operation of contemporary picoammeters with analog conversion of current into voltage has been presented. The influence of factors disturbing the i/u conversion in a passive as well as in an...

HYBRID MODELING OF BIOMEDICAL SYSTEMS AND MEASURING NONLINEAR CHARACTERISTICS OF BIOSIGNALS FOR IMPROVING QUALITY OF LIFE<br />

The main purpose of this paper is to present some metrological aspects of the new concept of hybrid modeling (combined physical and in silico) of biological systems as well as possible applications of nonlinear (symbolic...

Download PDF file
  • EP ID EP83124
  • DOI -
  • Views 95
  • Downloads 0

How To Cite

IRENEUSZ JABŁOŃSKI, ANUSZ MROCZKA (2008). FREQUENCY INDEXES OF RESPIRATION DURING INTERRUPTER EXPERIMENT. Metrology and Measurement Systems, 15(2), 153-164. https://europub.co.uk./articles/-A-83124