Frequency of HLA-B27 in Patients With Conductive System Disturbance and Implanted Permanent Pacemaker in Iran
Journal Title: International Journal of Cardiovascular Practice - Year 2017, Vol 2, Issue 1
Abstract
Introduction: HLA-B27 is considered as one of the causes of heart conductive disorders. We studied the frequency of HLA-B27 among Iranian patients who had undergone permanent pacemaker implantation. Methods: This descriptive and analytical study was performed among patients who underwent permanent pacemaker implantation. The questionnaire contains demographic data, underling diseases, and history of heart disease or heart surgery. The type of conductive heart disorder was mentioned there, too. We determined the regurgitation of aorta valve and its severity. Finally, HLA-B27 was accessed. All the data was entered in SPSS software and analyzed. Results: From a total of 103 patients entered in this study, only 6 (5.8%) were HLAB-27 positive. The disturbance of conductive heart disorders based on the HLA-B27 positive or negative patients was not statistically different. Patients with HLA-B27 mostly had regurgitation of the aorta valve. Conclusions: We concluded that the frequency of positive HLA-B27 genotype in patients with permanent pacemakers did not have any significant difference with the ones with negative HLA-B27 genotype. However; this genotype was associated with regurgitation of the aorta valve.
Acute Myocardial Infarction in a Patient With Elevated ST-Segment in aVR Lead and Diffuse ST Segment Depression in Other Leads: A Case Report
ST elevation in aVR in conjunction with diffuse ST depression in precordial leads may indicate occlusion of very proximal portion of the left anterior descending artery. We present a 54-year old man, with crushing retros...
Syncope during pregnancy in a patient with permanent cardiac pacemaker, due to increased pacing threshold.
A 22-year-old pregnant woman referred with syncope due to pacemaker malfunction. During the second trimester of pregnancy, the right ventricular (RV) lead pacing threshold increased and led to early generator depletion....
Change in Atrial Activation Pattern during Ablation of Atrial Flutter
Different types of supraventricular tachycardia have been reported in patients with history of surgical repair of Tetralogy of Fallot. This report presents appearance of focal atrial tachycardia during radiofrequency abl...
The Correlation between Serum Level of N-Terminal Pro-B-type Natriuretic Peptide and Gensini Score in Patients with Acute Coronary Syndrome
Introduction: N-terminal pro-B-type natriuretic peptide (NT-proBNP) has emerged as an important biomarker for developing the diagnosis and prognosis of cardiovascular diseases, as several studies have shown that serum le...
Venous Obstruction Following Pacemaker or Implantable Cardioverter-Defibrillator Implantation, Mini Review
Venous obstruction is relatively frequent following permanent pacemaker or implantable cardioverter-defibrillator (ICD) implantation. However, most of them are asymptomatic. Although the exact risk factor for this compli...