Functional outcome of distal end radius fractures treated with periarticular locking plates

Journal Title: International Journal of Orthopaedics Sciences - Year 2017, Vol 3, Issue 4

Abstract

Introduction: Currently, the majority of intra-articular fractures of the distal radius are managed by the volar approach. It is useful to have a family of plates to address this complex fracture pattern from both a volar and dorsal approach. The purpose of this study is to asses the management of comminuted distal radius fractures with fragment specific plate fixation. Material and Methods: The study was a retrospective study conducted including two trauma centers, over a period of one year. The primary outcome was measured by Patient Rated Wrist Evaluation (PRWE) at 3rd, 6th &12thmonth. Secondary outcomes were assessed with radiographic measures (shortening (ulnar variance), dorsal angulation, radial tilt, articular step) measured at presentation, postreduction and between 6 weeks and 12 months). Results: From a study population of 50 patients the study group showed 16% of type A, 36% of type B and 48% of type C fractures. At the 6 month follow-up, there was a mean of 150 of radial inclination, 2.5-mm radial shortening in 10 of the patients with type C fractures, no articular incongruity and a mean volar tilt of 3°. The score at 3rd month ranged from 45 to 70 with the mean score of 57.2±8.52, the score at 6th month ranged from 20 to 32 with the mean score of 25.3±3.6 and the score at 12th month ranged from 0 to 12 with mean score of 6.18±3.11. Conclusion: The lack of deterioration of the radiological parameters and the consistent improvement of the PRWE scores underline the versatility and stability provided by the fragment specific plates. Thus through this study we have come to the conclusion that fragment specific plates show better functional outcome in distal end radius fractures.

Authors and Affiliations

Dr. Ranganath BT, Dr. Pawan Kumar KM, Dr. Madhuchandra P

Keywords

Related Articles

Surgical management of compound fracture tibia using an unreamed interlocking nail

Background and Objectives: With increasing number of vehicles on the roads in India, complex trauma cases caused by traffic accidents have increased progressively. Fracture Tibia are among the commonest fractures sustain...

Comparatively increased complications in obese patients undergoing total hip arthroplasty through a direct anterior approach

Background: Direct Anterior IP replacement is a minimally invasive surgical technique. This approach involves a 3 to 4 inch incision on the front of the hip that allows the joint to be replaced by moving muscles aside al...

Occurrence of closed diaphyseal fractures of tibia in adults

This study has been done to evaluate the results and complications of intramedullary interlocking nail for closed diaphyseal fracture of tibia in adults. 50 adult patients of fresh tibial shaft fractures treated surgical...

A prospective study for definitive diagnosis of various arthropathies by synovial fluid analysis and percutaneous needle biopsy of synovium

Objectives: To evolve a diagnostic pattern of synovial fluid analysis, thus determining the usefulness of routine synovial fluid analysis as a simple diagnostic aid in various forms of arthritis. Background: Synovial flu...

Rapid diagnosis of “Fatigue” stress fractures using bone scintigraphy: A practical approach

Stress fractures can broadly classified into “fatigue” or “insufficiency” fractures depending on baseline bone health and amount of physical activity. Of these fatigue stress fractures present with a classical history of...

Download PDF file
  • EP ID EP482675
  • DOI 10.22271/ortho.2017.v3.i4l.116
  • Views 129
  • Downloads 0

How To Cite

Dr. Ranganath BT, Dr. Pawan Kumar KM, Dr. Madhuchandra P (2017). Functional outcome of distal end radius fractures treated with periarticular locking plates. International Journal of Orthopaedics Sciences, 3(4), 849-852. https://europub.co.uk./articles/-A-482675