Functional outcome of proximal femoral nail antirotation with helical blade fixation in extra capsular hip fractures in Himalayan region
Journal Title: International Journal of Orthopaedics Sciences - Year 2018, Vol 4, Issue 1
Abstract
Background: Extra capsular Intertrochanteric hip fractures occur in older age person. These are pathological fracture mostly (osteoporosis). Currently, these hip fractures are generally fixed with intramedullary or extramedullary implants. Implants preference mainly determined by the fracture classification (stable or unstable). Most common complications in standard proximal femoral nail and extramedullary implants is neck screw cutout. Due to Research and improvement in surgical technique incidence of neck screw cutout has reduced considerably but still remains the most common fixation failure with intramedullary implants. With this question in mind we did study to find out functional outcome of proximal femoral nail antirotation with helical blade fixation in extra capsular hip fractures in Himalayan region. Methodology: This prospective study was done on 75 patients with extra capsular hip fractures, for fixation of fracture, implant of choice were used proximal femoral nail antirotation with helical blade. Study were done during the period from September 2015 to August 2016. Informed written consent were taken from all patients. The study was approved by institutional ethical committee. We included > 45 year cases. Fracture was classified according to Boyd and griffin classification. Exclusion criteria were age<45 years, open intertrochanteric hip fractures, pathological fracture other than osteoporosis and polytrauma patients. After discharged from hospital patients were called in OPD for clinical and radiological evaluation at regular intervals (6wks. 12wks, 24 wks, 36 wks. and 48 wks). Results: 75 cases of hip intertrochanteric fractures were included and operated with proximal femoral nail antirotation with helical plate. Mean age of patients was 65.67±10.60 yrs. (45–94 yrs.). Based on preoperative x-rays fracture pattern 8 cases in type1, 18 cases in type 2 and 3 in each group, 31 cases in type 4 were recorded. Assessment of osteoporosis were done according to Singh index. Type 1 (n=8), type 2 (n=18), type 3(n=18), type 4 (n=31) were had mean Singh’s index 5.13, 4.59, 4.76, 4.70 respectively. Maximum number of patients (97.2%) showed sign of union between 18 to 24 weeks. The mean TAD was 24.69 mm±3.16 mm (Range 20-32mm). Union was achieved in all patients (n=66) at 48 weeks Harris Hip score was 38.47±13.14, 61.70+19.10, 83.44+12.24, 94.06+4.71, 98.18+4.27 and 98.68+1.84 respectively. At all the follow up intervals, Harris Hip score was improved (p<0.001). In our study overall outcome of patients (n=70) at 48 weeks who could complete the follow-up were good in 41 (58.5%), average in 25 (35.7%) and poor in 4 (5.7%) cases. Conclusion: Proximal femoral nail antirotation with helical blade gives better fixation even in osteoporotic intertrochanteric unstable femoral fractures. But preoperative assessment and planning, reduction and surgical technique should be followed. Intramedullary fixation has biological and biomechanical advantages over extra medullary fixation, helical blade has better bone holding due to less bone loss moreover also give cancellous bone impaction which lead to lower rate4 of implant losing and failure.
Authors and Affiliations
Akhilesh Singh Kushwaha, Pankaj Sharma, Mohit Dhingra, Pawan Rawat, Navneet Badoni, Puneet Gupta
A prospective study on functional outcome of fracture shaft of femur stabilised with reamed intramedullary nail
The incidence of femoral shaft fractures is on rise because of fast, high speed transportation and modern lifestyles. Internal fixation is the mainstay of treatment. Conventional plating is associated with high risk of i...
Clinico-radiological results of unstable trochanteric fractures treated with custom-made trochanteric stabilisation plate and dynamic hip screw (DHS)
Aim: To evaluate the clinico-radiological results of implantation of Custom-made Trochanteric stabilisation plate (TSP) along with Dynamic Hip Screw (DHS) in unstable trochanteric fractures and assess whether it prevents...
Management of Fracture Neck of Talus and Clinical Evaluation
Ankle injuries and Talar neck fractures are almost always the result of a high-energy trauma. It always remains a topic of debate whether talar neck fractures require emergent reduction. Most orthopaedic surgeons recomme...
Functional outcome of intertrochanteric fractures treated with dynamic hip screw and influence of tad over it - A prospective study
Fractures of proximal femur are amongst the most often encountered fractures by orthopedic surgeons. Many treatment techniques are described in literature, but internal fixation with Dynamic Hip Screw (DHS) is the gold s...
Comparative study of debridement, fusion and instrumentation via single stage anterior or single stage posterior approach in dorsolumbar spinal tuberculosis
Background: There is controversy regarding approach for surgical treatment of dorsolumbar spinal tuberculosis. The aim of this study is to make a comparative study on the basis of clinico-serological, radiological, neuro...