Grading of unstable distal radius fractures and its evaluation using JESS fixation
Journal Title: Indian Journal of Orthopaedics Surgery - Year 2017, Vol 3, Issue 3
Abstract
Introduction: Unstable distal end radius fractures are a common entity with various treatment options. The degree of instability varies with each fracture and it has a bearing on the treatment outcome. We are trying to grade the instability and its use in predicting treatment outcome. Materials and Method: 48 adult patients with unstable distal radius fractures were classified into three grades according to our instability grading. All were treated with Joshi’s external stabilizing system and their anatomical and functional results were analyzed at one year. Result: 91% had excellent or good functional results and there were statistically significant differences in functional outcome among the three grades. Conclusion: The proposed grading system is simple and will help to predict functional out come and duration of JESS fixation in unstable distal radius fractures.
Authors and Affiliations
Arun Gopalakrishnan, Sreesobh K. V
Fixation in bimalleolar fractures of ankle-a comparative study between fibula plating versus intramedullary nailing with medial malleolar screw
Background: A bimalleolar ankle fracture is unique in the sense that ankle is the distal most weight bearing joint and locomotion depends upon stability of the ankle mortise. The best option for management of bimalleolar...
Long PFN nailing in comminuted high subtrochanteric fractures femur in lateral position on ordinary table
Introduction Most of the hip fractures are managed in supine position on a fracture table with foot attached to foot plates and biplanar fluoroscopy supervision under carm But this procedure has its own difficulties in m...
Unusual presentation of the wartenberg syndrome as writers cramp
A 57 year old male, clerk by profession, presented to us with complaints of right thumb pain with limitations of movements at thumb, thinning of the thumb and deformity of nail. The patient had right thumb pain in doing...
Role of hip abduction brace in preventing impending failure in PFN
Introduction The hip abduction brace is an orthotic device made after taking individual measurements and works on the principle by assisting or resisting the movements of joint and bypass the load on Implant and hip join...
Reliability of optoelectronics motion capture analysis in hip range of motion
Purpose: The purpose of this study was to determine the reliability of optoelectronic motion capture analysis to determine the hip range of motion. Materials and Methods: Fifteen recreationally active male participants (...