Abstract

The quality of electrical power is the major important goal of all researchers. In utility power system it has been observed that harmonics build a major role in reducing the quality power. These harmonics caused by nonlinear loads. Many consumers appliances demand quality power continuously for their operation. The performance of the end user equipment is heavily dependent on the quality of power supplied to it. This power is affected by various external and internal factors. They are like voltage and frequency variations, faults, outages etc. The solution to overcome these problems is to filter out these harmonics. For this purpose, there are many filters topologies are proposed and studied in the literature to eliminate harmonics currents. In this paper, three phase 4-wire hybrid filter is proposed with Self-Tuning-Filter (STF).in this paper, a hybrid power filter is proposed to solve problems of line harmonic currents and neutral line currents of three phase four wire power distribution system. The hybrid filter is three-arm power converter with split capacitors. This configuration uses a smaller number of power electronic switches to reduce the manufacturing cost. The use of STF in the control method can optimize the performance of this topology regarding to classical one. The proposed control strategy is simulated in MATLAB Simulink and the results are presented.

Authors and Affiliations

Mohamed Muftah Saleem Abdusalam

Keywords

.

Related Articles

Performance Analysis of PV Solar Power System

The state of Chhattisgarh is blessed with high solar radiation intensity and has capacity for large solar energy generation. With increasing energy demand and rapid use of fossil fuel has made pressure on thermal power g...

An Endeavor of Frequency Regulation by Free Governor Mode of Operation in Bangladesh Power System

For satisfactory, secured and economic operation of a power system, the frequency should remain nearly constant. The only way to maintain system frequency within an acceptable range is to make balance between generation...

Design and Realization of Readout for Beam Loss Detector of Accelerator Particles

During construction of the accelerator machine to achieve optimal transmission, the fraction of beam particles lost has to be controlled. It is why a careful analysis of the location and time structure of possible losses...

Design Modeling and Simulation of Fuzzy Controlled Svc for Long Over Head Transmission Line

The basic control objectives of a power system are system voltage control, system frequency control, protection and economic operation. Reactive power control is a subset of overall system control and stability. A power...

Grid Monitoring using Solar SCADA Dataset

Grid is framed as a planned nationwide network that makes use of information so as to deliver electricity in an efficient, reliable and secure manner. This entire electrical system is very difficult to monitor because an...

Download PDF file
  • EP ID EP421917
  • DOI 10.9790/1676-1306010106.
  • Views 144
  • Downloads 0

How To Cite

Mohamed Muftah Saleem Abdusalam (2018). Harmonics Currents Cancelation by Three-Phase 4-wire Hybrid Active Power Filter with Split Capacitors and STF. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 13(6), 1-6. https://europub.co.uk./articles/-A-421917