Hybrid Integrated Microfluidic Device for Sample Preparation and qPCR on an EWD Platform
Journal Title: Biomedical Journal of Scientific & Technical Research (BJSTR) - Year 2019, Vol 19, Issue 1
Abstract
The molecular diagnosis of blood infections is challenging because pathogens exist in the bloodstream in very low concentrations. Consequently, such sparse target populations require DNA extraction and purification from large volume biofluids. This work utilizes the advances in microfluidic technologies to demonstrate the nucleic acid purification - qPCR sequence detection workflow for this application. Immiscible Phase Filtration (IPF) for nucleic acid purification and Electrowetting-on Dielectric (EWD) droplet actuation are combined on a hybrid microfluidic device that translates from large volume sample-to-small-volume analysis. After IPF reduces the sample volume from a milliliter-sized lysate to a microliter-sized eluent, EWD can be used to automatically prepare the PCR mixture. This step begins with transporting droplets of the PCR reagents to mix with the eluent droplets. Suitable assays, microfluidic stages, and auxiliary systems are described. The extent of purification obtained per IPF wash, and hence the number of washes needed for uninhibited qPCR, are determined via onchip UV absorbance. The performance of on-chip qPCR, particularly the copy number to threshold cycle correlation, is characterized. Lastly, the above developments accumulate to an experiment that includes the following on-chip steps: DNA purification by IPF, PCR mixture preparation via EWD, and target quantification using qPCR - thereby demonstrating the core procedures in the proposed approach.The requirement to detect trace, quantifiable amounts of DNA in large-volume biomedical samples requires advanced DNA preparation techniques using modern technologies to facilitate DNA isolation, purification and analysis by Quantitative PCR (qPCR). Thus, a key step in DNA analysis is high efficiency Nucleic Acid (NA) purification. Conventional laboratory-based magnetic bead purification involves repetitive pipetting and centrifugation. For example, depending on the starting sample, as many as seven washes may be necessary for removing the contaminants entrapped in the bead pellet, adsorbed on the walls of reaction tubes, or remaining in the solution after aspirating the supernatant [1]. As a result, without access to costly robots this process is labor intensive.
Authors and Affiliations
Hsu BN, Fair RB
The Pediatric Neurosurgery in Northeast Brazil – Recife Has Become a Reference Centre
Brazil is the biggest Latin American country, with approximately 8,500,000Km², almost 195,000,000 inhabitants, close to 23 inhabitants perKm², 36% under 19 years old, with an infant mortality rate of 20.7 per 1000 live b...
Senior Solutions: Direct Composite Fixed Bridges
Remaining teeth in Americans according to the NIH’s 2004 report state that only 22 out of 32 teeth per person are present in people 50 to 64 years of age. That computes to 10 missing teeth per person at 50 or ab...
Dynamic Model-Based Monitoring of Human Thermal Comfort for Real-Time and Adaptive Control Applications
Thermal comfort and sensation are important aspects of the building design and indoor climate control as modern man spends most of the day indoors. Conventional indoor climate design and control approaches are based on s...
Effect of Inter and Intra-Row Spacing on Yield and Yield Components of Lettuce (Lactuca Sativa) in South East Tigray, Ethiopia
Development of recommendation on appropriate plant spacing is one of the important agronomic practices to increase the productivity of lettuce. Therefore, a field experiment was conducted to assess the response of Tesfa...
Dysfunction of Endothelial Cell Precursors in Heart Failure Development
Heart failure (HF) a leading cause of premature death in patients with established cardiovascular (CV) disease. Although the global burden of HF is increasing, there is no evidence regarding promising results that improv...