IMPROVED THE ADAPTATION FOR THREE PHASE ACTIVE FILTER UNDER NON-IDEAL-LOAD USING SAMPLE CURRENT CONTROL

Abstract

In this paper, a comparison between sample current control and direct current control to show the efficiency of the two current control method of Active Power Filter. The main function of the scheme was a duty by the two-level three phases inverter. According to the classic approach, transistors are converted depending on the sign of the current error, in turn, sampled at equal intervals. Both methods follow the synchronous toggle principle. In the first method, the current vector at the end of the interval is predicted for two possible cases when the operating voltage vector towards the current fault or zero voltage vector is applied. An error generates a smaller current error at the end of the selected sampling period, thus reducing the switching frequency. In the second method, the most appropriate operating voltage vector will succeed in zero vectors over the same period. A simple algorithm is used to calculate the duty cycle to achieve the smallest possible error. Both methods are simulated with three different load modes: no load, RL load, and nonlinear load. At the end of the article, the behavior of the second method, SCC, is worth more. The simulation results demonstrate the viability and effectiveness of the two technique of current control in reducing the ripple, losses, and Total Harmonic Distortion of supply current.

Authors and Affiliations

Huynh Le Minh Thien, Nguyen Xuan Tien, Tran Thanh Vu, Ho Van Cuu

Keywords

Related Articles

WATER RESOURCES OF TRANSBOUNDARY RIVERS OF THE REPUBLIC OF KAZAKHSTAN: MANAGEMENT PRINCIPLES, METHODS AND MECHANISM

This article provides theoretical and methodological provisions on the management of transboundary water resources in Kazakhstan. This article outlines the basic definitions, goals, objectives, approaches, principles and...

LOW COST SOFT ROBOTIC GRIPPERS FOR RELIABLE GRASPING

Soft robotic gripper shows valuable role in those tasks where robotic gripper met delicate objects. Comparison with rigid grippers, soft robotic gripper can grip/manipulate variety of target objects. This paper presents...

DESIGN OF SOLID WASTE SEPARATION EQUIPMENT IN BAGHDAD CITY

A massive number of weapons and solid waste are experienced since 1980 in Baghdad. The new government was forced to bury the solid waste in vast tracts, which is limited to waste pressing only without any separation proc...

EVALUATION OF VELOCITY VARIATION IN A CHUTE AS A FUNCTION OF ROUGHNESS

The present paper establishes numerical simulations with CFD packages for analyze the velocity variation as a function of roughness in a chute, and to determine the use of OpenFOAMĀ® CFD package for this phenomenon. Exper...

CORRELATION OF OVERALL HEAT TRANSFER COEFFICIENT IN THE THREE ZONES OF WIRE AND TUBE CONDENSER

Numerical and experimental analysis has been studied to estimate the overall heat transfer coefficient in the three zones along wire and tube condenser. The model is based on the empirical formulation of the refrigerant...

Download PDF file
  • EP ID EP572229
  • DOI 10.26480/jmerd.03.2019.76.80
  • Views 66
  • Downloads 0

How To Cite

Huynh Le Minh Thien, Nguyen Xuan Tien, Tran Thanh Vu, Ho Van Cuu (2019). IMPROVED THE ADAPTATION FOR THREE PHASE ACTIVE FILTER UNDER NON-IDEAL-LOAD USING SAMPLE CURRENT CONTROL. Journal of Mechanical Engineering Research & Developments (JMERD), 42(3), 76-80. https://europub.co.uk./articles/-A-572229