Intra- and Inter-operator Reproducibility Analysis of Automated Cloud-based Carotid Intima Media Thickness Ultrasound Measurement

Journal Title: Journal of Clinical and Diagnostic Research - Year 2018, Vol 12, Issue 2

Abstract

ABSTRACT Introduction: Manual carotid intima media thickness (cIMT) measurements are tedious and prone to errors. Further, these measurements are subject to intra and inter-observer variability. Several studies affirm the requirement for an automated system for cIMT computation, but they still suffer from low reproducibility and lack standardisation towards clinical trials. The novelty of this study is to demonstrate the intra and inter-operator reproducibility for a cloud-based automated cIMT measurement system. Aim: To demonstrate the reproducibility analysis and validation of cloud-based automated cIMT measurement systems. Materials and Methods: The reproducibility analysis was performed by two operators at three separate times (six auto readings: 1a, 1b, 1c, 2a, 2b, 2c). For validation of cloud-based cIMT measurement system, we compared the automated readings against the manual readings by the expert. The expert readings were provided by two observers who manually traced the LI/MA borders at two separate times (four manual readings: 1a, 1b, 2a, 2b). Further, we also performed the variability analysis of the manual readings. Results: The mean Correlation Coefficients (CC) for six intra and nine inter-operator reproducibilities between the auto readings pairs were: 0.99 (p<0.001) and 0.96 (p<0.001), respectively. The mean CCs for two intra and four inter-observer variabilities between the manual readings pairs were 0.94 (p<0.001) and 0.95 (p<0.001), respectively. The accuracy computed between the mean of the six auto readings against each of the four manual readings were: 96.88%, 97.26%, 99.04%, and 98.95%, respectively. While keeping the threshold at 0.9 mm, the ROC using eight combinations give a mean AUC of 0.97±0.01. Conclusion: The proposed cloud-based automated cIMT measurement software system showed high reproducibility. The system can be adapted for routine or clinical (pharmaceutical) trial modes.

Authors and Affiliations

Luca Saba, Sumit K Banchhor, Tadashi Araki, Harman S Suri, Narendra D Londhe, John R Laird, Klaudija Viskovic, Jasjit S Suri

Keywords

Related Articles

Er:YAG and Diode Lasers in Treatment of Peri-Implantitis–A Case Report

ABSTRACT One of the leading causes of dental implant loss in the present time is peri-implantitis. This paper describes a clinical case of peri-implantitis treatment using Er:YAG and a 980-nm diode laser. In the present...

The Correlation between Body Mass Index and Vasopressor Need after Spinal Anaesthesia for Cesarean Section

ABSTRACT Introduction: Hypotension is one of the common complications of spinal anaesthesia in mothers undergoing cesarean delivery. Vasopressor such as ephedrine or phenylephrine are the most common drugs employed to tr...

Association between Socioeconomic Status and Diabetes Mellitus: The National Socioeconomics Survey, 2010 and 2012

Introduction: The prevalence of Diabetes Mellitus (DM) is increasing, globally. However, studies on the association between Socioeconomic Status (SES) factors and DM have mostly been conducted in specific areas with rath...

An Evaluation of the Numbers and Locations of Coronary Artery Disease with Some of the Major Atherosclerotic Risk Factors in Patients with Coronary Artery Disease

Introduction: Despite definite recognition of major atherosclerotic risk factors, the relationship between the pattern of coronary artery disease and these risk factors is unknown. Aim: The aim of this study was to ident...

Predictive Regression Equations of Flowmetric and Spirometric Peak Expiratory Flow in Healthy Moroccan Children

Introduction: Peak Expiratory Flow (PEF) has never been characterised among healthy Moroccan school children. Aim: To study the relationship between PEF and anthropometric parameters (sex, age, height and weight) in heal...

Download PDF file
  • EP ID EP514676
  • DOI 10.7860/JCDR/2018/34311.11217
  • Views 52
  • Downloads 0

How To Cite

Luca Saba, Sumit K Banchhor, Tadashi Araki, Harman S Suri, Narendra D Londhe, John R Laird, Klaudija Viskovic, Jasjit S Suri (2018). Intra- and Inter-operator Reproducibility Analysis of Automated Cloud-based Carotid Intima Media Thickness Ultrasound Measurement. Journal of Clinical and Diagnostic Research, 12(2), 1-11. https://europub.co.uk./articles/-A-514676