Intra-Cavity Loss Element Method for Measurement of the Small Signal Gain of a TEA CO2 Laser

Journal Title: International Journal of Fundamental Physical Sciences - Year 2012, Vol 2, Issue 4

Abstract

The small-signal gain coefficient of a TEA CO2 laser has been measured through the implementation of a variable polarization intra-cavity loss element. Charging voltage dependence of the gain property of the laser has been investigated. The advantage of this method is that no probe laser system is required. The results have been agreed with experimental data obtained by conventional oscillator-amplifier method.

Authors and Affiliations

M Aram, Z Porhasannejad, E Aghayare, S Behrouzinia

Keywords

Related Articles

Pick up pattern from logic fuzzy in mathematics for zonation of ‎landslide hazard

First landslide hazard zonation provided based on Fuzzy logic by landslide area laid on the Slope map, ‎Geology( lithology) map, Aspect map. Then, these maps classes of priority and coming next determine based ‎on existi...

Understanding requirements for a holistic tool for Ecodesign-first steps

Today, technological developments increase very fast and plenty of hi-tech products are seen in the global market. With the influence of consumerism, these products are sold frequently and their life cycles become s...

Behavior of elliptical objects in general theory of relativity

The simplest solution of Einstein's field equations is Schwarzschild solution. This solution is not able to describe for any nonspherical shaped objects. Some stars and galaxies are in ellipsoidal. Consequently, the grav...

Crystal Growth and Powder X-Ray Diffraction Data of Cadmium Zinc Tellurium (Cd0.29Zn0.71Te)

X-ray powder diffraction data for a new Cadmium Zinc Tellurium compound synthesized by Bridgman technique is reported. The unit cell dimensions were determined from diffractometer methods using CuK radiation, and the in...

Quality and Sustainability Criteria in Purchase Decisions of Teenagers

The raising sustainability awareness of consumers has brought the discourse about environmental impacts of products into pulic discourse. Industry has had to respond to this demand for sustainable products. Among the dif...

Download PDF file
  • EP ID EP599323
  • DOI 10.14331/ijfps.2012.330038
  • Views 87
  • Downloads 0

How To Cite

M Aram, Z Porhasannejad, E Aghayare, S Behrouzinia (2012). Intra-Cavity Loss Element Method for Measurement of the Small Signal Gain of a TEA CO2 Laser. International Journal of Fundamental Physical Sciences, 2(4), 58-60. https://europub.co.uk./articles/-A-599323