INVESTIGATION AND CALCULATION OF VALLEYS OF OUTGOING FROM SUBSTATION GROUNDING CONDUCTORS FOR SHORT-CIRCUIT IN SINGLE-PHASE SHORT OF ELECTRICAL GRID
Journal Title: Електротехніка і Електромеханіка - Year 2015, Vol 0, Issue 2
Abstract
Introduction. Earthing device electrical substation in modern conditions must meet both the requirements of electrical safety of people and animals, as well as electromagnetic compatibility requirements established her electrical equipment. These requirements are intended to address issues of protection against surges and interference caused by lightning impulse currents and switching. Aim. To investigate the distribution of single-phase short-circuit current in the substation grounding devices. Task. On the basis of the proposed design scheme of substitution substation grounding device, consisting of a substation earthing system and «cable-supported» an algorithm for calculating the resistance of the grounding device substation and distribution of single-phase short-circuit current on the circuit elements. Method. Mathematical modeling and calculation engine. Results. On the basis of calculations and studies analyzed the current distribution of single-phase short-circuit between the substation earthing system and earthing «rope-reliance». Studies carried out for the actual range of variation of the circuit parameters, showed that the earthing resistance substation substantially affects the current distribution in the one-phase short circuit fault. For example, using the graph shows that with increasing resistance grounding system of "rope-supported" the proportion of single-phase short-circuit current flowing from the substation earthing increases, while the proportion of single-phase short-circuit current flowing from the grounding device supports decreases and vice versa. In addition, when rationing grounding systems at substations for the touch voltage is necessary to analyze all the possible modes of operation of the network, which is substationed. Conclusion. The results obtained are recommended to take into account in the design of grounding systems at substations.
Authors and Affiliations
I. V. Nizhevskyi, V. I. Nizhevskyi, B. Ynoyatov, S. Nasryddyny
ON SUBSTANTIATION OF SELECTION OF ECONOMIC AND MATHEMATICAL METHODS FOR THE ASSESSMENT OF ENERGY EFFICIENCY OF PRODUCTION FACILITIES
Research purpose is generalization and further development of economic- mathematical methods for ensuring energy-efficient operation mode of production facilities. The above methods can be used for selection of the most...
SYNTHES OF ROBUST ACTIVE SHIELDING SYSTEMS OF MAGNETIC FIELD GENERATED BY GROUP OF HIGH-VOLTAGE POWER LINES
Aim. The synthesis of robust active shielding system of magnetic field, generated by group of high voltage power lines for reducing the induction of the initial magnetic field to the sanitary standards level and reducing...
EXPERIMENTAL APPROBATION OF AN ELECTRODYNAMIC DIRECT ELECTRIC SYSTEM FOR EXTERNAL AUTOMOBILE BODY REPAIR
The article presents results of experimental research on an electrodynamic system with direct current flow for external automobile body repair. A possibility of specifying the direction of increasing magnetic pulse attra...
A TECHNIQUE OF FULL-SCALE MEASUREMENTS OF THE RESISTANCE OF THE GROUNDING DEVICE
Purpose. The measurements of the resistance of grounding devices for various purposes using a three-electrode installation under real conditions are considered. Methodology. On the basis of the use of a three-electrode i...
ELECTRIC GENERATOR IN THE RECUPERATION SYSTEM OF THE ENERGY FROM MECHANICAL OSCILLATIONS IN VEHICLES
The paper deals with the system of mechanical energy recuperation of vehicles in the useful electric energy accumulated in the rechargeable battery. This system creates an additional power supply on board of the vehicle...