INVESTIGATION OF MODEL TRANSFORMER INSULATION BEHAVIOR DURING PD ACTIVITY IN DI-BENZO-DI-SULFIDE SULPHUR CONTAMINATED TRANSFORMER OIL USING ONLINE TAN DELTA MEASUREMENT

Journal Title: Engineering and Technology Journal - Year 2022, Vol 7, Issue 09

Abstract

Sulphur can be present in mineral insulating oil and can manifest in stable, highly reactive and corrosive form. The corrosive sulphur reacts with the copper conductor in transformer and forms semi conductive copper sulphide at the surface of the copper conductor. The paper insulation used on the copper conductor may get damaged due to copper sulfide deposits which also affect the partial discharge activities prevalent in the transformer paper-oil insulation. The affect of Sulphur on model transformer paper-oil insulation is studied with online measurement of Dissipation factor (tanδ) and partial discharges (PD). The paper presents results of the investigatory work carried out with on-line tanδ and PD measurements made during experiments with Paper covered copper conductor (PCCC) in presence of Di-Benzo-Di-Sulfide contamination in transformer oil.

Authors and Affiliations

 L. Sanjeev Kumar,   B. Ramachandra,  S. Senthil Kumar 

Keywords

Related Articles

COMPARISON OF PROBABILITY IMPACT MATRIX AND FUZZY LOGIC METHODS FOR RISK ANALYSIS OF RURAL INFRASTRUCTURE PROJECTS IN INDONESIA

Through the provision of facilities and infrastructure in the Village, it can be used as an effort to empower the community to accelerate regional economic development that is effective and robust. In its implementation,...

DESIGN AND ANALYSIS OF TWO-STAGE OPERATIONAL TRANSCONDUCTANCE AMPLIFIER WITH COMPENSATION CAPACITOR

For designing of high-performance analog circuits is still a hard task towards reduced supply and increased unity bandwidth. OTA is the basic element with highest power dissipation in many applications. In a handheld dev...

The Influence of Thermal Disorders on XAFS Debye-Waller Factor of Nickel

The anharmonic X-ray absorption fine structure Debye-Waller factor of Nickel has been analyzed under the influence of thermal disorders. This Debye-Waller factor was calculated in explicit forms using the anharmonic corr...

Optimizing Electric Vehicle Performance, Range and Parameter Estimation through NEDC Urban and Suburban Analysis using MATLAB

This research paper focuses on electric vehicle (EV) driving range and parameter estimation, with an emphasis on analyzing the New European Driving Cycle (NEDC) urban and suburban drive cycles. By examining these drive c...

MORPHOLOGICAL, CHEMICAL, AND THERMAL CHARACTERIZATION OF TOBACCO STALK FOR APPLICATION IN COMPOSITE MATERIALS

The main objective of this study is to analyze the use of tobacco stalk to develop new composite materials. For this purpose, tests and analyses were carried out to characterize the morphological, thermal, and chemical p...

Download PDF file
  • EP ID EP709703
  • DOI 10.47191/etj/v7i9.02
  • Views 66
  • Downloads 0

How To Cite

 L. Sanjeev Kumar,    B. Ramachandra,  S. Senthil Kumar  (2022). INVESTIGATION OF MODEL TRANSFORMER INSULATION BEHAVIOR DURING PD ACTIVITY IN DI-BENZO-DI-SULFIDE SULPHUR CONTAMINATED TRANSFORMER OIL USING ONLINE TAN DELTA MEASUREMENT. Engineering and Technology Journal, 7(09), -. https://europub.co.uk./articles/-A-709703