Investigations on the Innovation Model of Exergy Effectiveness of Air Conditioning System for Operating Cleanrooms

Journal Title: Energy Engineering and Control Systems - Year 2017, Vol 3, Issue 1

Abstract

The issue of fuel and energy saving is a top priority for energy technological systems (ETS) such as air conditioning systems (ACS). Thus, reduction of energy consumption for ACS requires optimization of these systems which can be obtained on the basis of the exergy analysis. This analysis takes into account not only the quantity of the energy being consumed but also its quality. By taking into account the exergy during calculation of balances and various characteristics of ETC (including ACS) the scientific and engineering problems can be solved in a simple and easily understandable way. Frequent mistakes caused by ignoring the quality of transformations can be avoided. Innovation mathematical research model of the existing central straight flow air conditioning system for operating cleanrooms with the aim of computer estimation of its energy effectiveness by virtue of exergetic output-input ratio depending on different factors, which have influence on its operation, is presented in this article. The dependence of exergetic output-input ratio ηe of the existing air conditioning system on temperature difference between the inside and the supplied air ∆tS=tin – tS was defined based on this model.

Authors and Affiliations

Dmytro Harasym, Volodymyr Labay

Keywords

Related Articles

Technique for Evaluating the Uncertainty of Enthalpy of Water and Steam for Thermal Energy Metering Systems

The paper presents an analysis of existing techniques for calculating the enthalpy of water (steam). Based on the analysis the techniques were defined that should be applied for computer-aided design of thermal energy me...

Gas Dynamical Capillary Flowmeters of Small and Micro Flowrates of Gases

The possibility of application of glass capillary tubes (CTs) as sensors of small and micro flowrates of gases was justified. The accuracy of a number of CTs flowrate equations was analyzed on the basis of experimental s...

Controlled Switched Reluctance Motors with Energy Capacitor

One of the most simple in terms of construction, the most practically feasible and reliable motors is a switched motor with salient-pole stator, concentrated coils and its winding and toothed passive rotor. Such motor is...

Peculiarities of Non-Stationary Pressure Measurement in Real Time

Nowadays, industrial development creates new and more complex processes leading to emergence of specific conditions for use of sensors and therefore specific measurement tasks. These circumstances lead to new requirement...

System of Mode Variables of Energy Circuits

Modern energy systems feature diversity of elements and combination of processes and phenomena of various physical natures. Mathematical modelling of such systems relies on the tools of the theory of energy circuits. One...

Download PDF file
  • EP ID EP256977
  • DOI 10.23939/jeecs2017.01.015
  • Views 73
  • Downloads 0

How To Cite

Dmytro Harasym, Volodymyr Labay (2017). Investigations on the Innovation Model of Exergy Effectiveness of Air Conditioning System for Operating Cleanrooms. Energy Engineering and Control Systems, 3(1), 15-22. https://europub.co.uk./articles/-A-256977