Large Banks of Negative Differential Resistance Nonlinear Loads: A Hidden Threat to Power System Quality
Journal Title: Mehran University Research Journal of Engineering and Technology - Year 2018, Vol 37, Issue 1
Abstract
DSM (Demand Side Management) is a short term and comparatively low cost solution for energy starved countries. Replacement of IB (Incandescent Bulbs) with CFL (Compact Fluorescent Lamps) has proved its success throughout the world. The same solution, at larger scale, was proposed to Pakistan to mitigate power shortage on short term basis. Accordingly in year 2008, ADB (Asian Development Bank) conducted a study and it was found that replacement of conventional IB with 30 million CFL will result into series of benefits for the stake holders and above all the Environment. The study, unfortunately didn’t take enough consideration of effect of CFLs on the power system being nonlinear device and so the power quality issues remained a secondary consideration. The focus of this paper remains on the effect of such non-linear load on consumers, it also envisages the erratic behaviour of such large penetration of CFLs on direct single phase, three phase, digital as well as electromechanical energy meters, under different loading conditions e.g. resistive load, SMPS (Switch Mode Power Supply), half and full-wave rectifiers. It also reflects harmonic pollution caused by CFLs, their effect on power system quality and the registration ability of electromechanical as well as digital energy meters. To this end Harmonic spectrum was recorded up to the 31st harmonic.
Authors and Affiliations
M. Ahmad, T. Izhar
A Robust Color Image Watermarking Scheme using Chaos for Copyright Protection
An exponential growth in multimedia applications has led to fast adoption of digital watermarking phenomena to protect the copyright information and authentication of digital contents. A novel spatial domain symmetric co...
Comparison of Klinkenberg-Corrected Gas and Liquid Permeability in Kirthar Fold Belt Tight Gas Sands
A detailed laboratory study was carried out to investigate the controls and differences between Klinkenbergcorrected gas and liquid permeability. For this reason outcrop core samples were collected from Kirthar fold belt...
Determination of Arsenic and Health Risk Assessment in the Ground Water of Sindh, Pakistan
As (Arsenic) is one of the lethal element present at the various locations of the world, putting human beings in danger by polluting the water. Arsenic Kit and atomic absorption spectrometer were used to determine As in...
Adaptive HAR System to Improve Recognition Accuracy
HAR (Human Activity Recognition) system becomes complex, inefficient and less accurate as we keep on adding new activities into the system; because it follows a specific procedure for activity recognition, from raw data...
Effect of Lowering Twist Levels on Quality Parameters of Rotor Spun Cotton Yarn
Investigations were made to explore the influence of lowering twist level on quality characteristics of rotor spun yarn. Three levels of yarn linear density (i.e. 40, 35 and 30 tex) and five levels of twist (i.e. 700, 60...