Load Flow Analysis on 400 KV Sub-Station- A Case Study

Abstract

The paper attempts to a basic concept for a Load flow analysis with a sense of the optimal load flow analysis The objective of an Optimal Power Flow (OPF) is to find steady state operation point which minimize generation cost, loss etc. or maximize social welfare, load ability etc. while maintaining an acceptable system performance or limits on generators active and reactive powers, line flow limits, etc. The paper contains a overview of the session followed by summaries. Load flow analysis software package develops by the author use MI-POWER. To demonstrate its use, a simple 19-bus system was selected as a example of 400kV SOJA substation. The purpose of this paper is to present a comprehensive survey of various optimization methods to solve load flow and optimal load flow problems

Authors and Affiliations

Takshak V Rabari

Keywords

Related Articles

A Design of Rectangular Microstrip Patch Antenna Based on Fractal Geometry for Wideband Applications

This manuscript presents the novel design of rectangular microstrip patch antenna based on fractal techniques for wideband applications. In this design, T-slots are introduced in rectangular patch geometry by varying the...

Study on Strongly Pseudo Irregular Fuzzy Graphs

In this paper, Some results on Strongly pseudo Irregular Fuzzy Graphs and Strongly pseudo total Irregular Fuzzy Graphs are established. Comparative study between Strongly pseudo Irregular Fuzzy Graphs and Strongly pseudo...

Fractional Order Control System

This paper includes the study of fractional order PID control system. In this firstly the study of step input signal in time domain for getting transient response using normal control system is done. Then with the use of...

Literature Survey on Establishing Wireless Sensor Networks Using Otway Rees Protocol

Wireless sensor network has many application such as environment sensing, building safety monitoring, earthquake prediction etc. Security is critical issue in sensor networks. A fundamental security service is to establi...

A Hybrid PAPR Reduction Scheme Using Selective Mapping and Amplitude Clipping

High information rate is the major requirement of modern communication systems. As there is the scarcity of spectrum OFDM proves itself very useful. In OFDM the subcarriers are made adjacent and orthogonal to each other...

Download PDF file
  • EP ID EP242702
  • DOI -
  • Views 110
  • Downloads 0

How To Cite

Takshak V Rabari (2015). Load Flow Analysis on 400 KV Sub-Station- A Case Study. International journal of Emerging Trends in Science and Technology, 2(12), 3370-3375. https://europub.co.uk./articles/-A-242702