Luminescence of X-ray induced radiation defects in modified lithium orthosilicate pebbles with additions of titanium dioxide

Journal Title: Energetika - Year 2017, Vol 0, Issue 0

Abstract

Modified lithium orthosilicate (Li4SiO4) pebbles with additions of titanium dioxide (TiO2) are designed as a possible tritium breeder ceramic for the helium cooled pebble bed (HCPB) test blanket module. Additions of TiO2 were chosen to enhance mechanical properties of the tritium breeder pebbles. The formation of radiation defects (RD) in the modified Li4SiO4 pebbles with a different content of TiO2 was studied by X-ray induced luminescence (XRL) technique. After XRL measurements the accumulated RD were also analyzed by thermally stimulated luminescence (TSL) and electron spin resonance (ESR) spectrometry. XRL spectra consist of several bands with maxima at around 430, 490, 690, 700 and 800 nm. The XRL band with a peak at 490 nm could be associated with intrinsic defects in Li4SiO4 matrix whereas all the other maxima at lower photon energies are the result of the addition of TiO2.

Authors and Affiliations

Janis Cipa, Gunta Kizane, Arnis Supe, Aleksejs Zolotarjovs, Arturs Zarins, Larisa Baumane

Keywords

Related Articles

Power quality issues in smart grids with photovoltaic power stations

Problems of power quality and electric energy accounting often occur in networks with large pervasion of photovoltaic (PV) elements on rooftops of household and office buildings. In smart grids, including PV arrays elect...

Representation of wind power generation in economic models for long-term energy planning

The representation of wind power plants electricity generation in economic models for energy planning is problematic, since generation in wind power plants is variable and it is not possible to predict accurately enough...

Calculation and comparative analysis of the mean energy expended per ion pair by electrons in water and hydroxyl radical

Researches of physical and chemical processes occurring in water during the interaction with particles (electrons, ions, photons, etc.) are interesting for a wide range of physical and applied problems in astrophysics, r...

Monte Carlo simulation of district heating system short-term operation in electricity markets

Energy generation in district heating (DH) systems is usually done in combined heat and power (CHP) units which can efficiently produce both useful heat and electric power. There can also exist heat only boilers, electri...

Numerical evaluation of systematic errors of a non-invasive intracranial pressure measurement

Intracranial pressure (ICP) monitoring procedure can be applied to aid in secondary brain damage prevention. A high invasiveness of commonly used ICP measuring methods poses a risk of complications, and therefore new non...

Download PDF file
  • EP ID EP260807
  • DOI 10.6001/energetika.v63i3.3562
  • Views 109
  • Downloads 0

How To Cite

Janis Cipa, Gunta Kizane, Arnis Supe, Aleksejs Zolotarjovs, Arturs Zarins, Larisa Baumane (2017). Luminescence of X-ray induced radiation defects in modified lithium orthosilicate pebbles with additions of titanium dioxide. Energetika, 0(0), 113-120. https://europub.co.uk./articles/-A-260807