Mainstream Capnography Correlates Well with Central Venous Carbon Dioxide Levels in Non-intubated Children in PACU

Journal Title: Journal of Clinical and Diagnostic Research - Year 2019, Vol 13, Issue 3

Abstract

ABSTRACT Introduction: Monitoring exhaled Carbon Dioxide (CO2) in non-intubated patients is challenging but has value for detecting hypoventilation, apnoea and hypercarbia. The study investigated a mainstream mask capnography system (cap-ONE®) especially designed for children. Aim: To compare the accuracy of peak exhaled CO2 (PexCO2) using mainstream mask capnography to partial pressure of central venous CO2 (PcvCO2). Materials and Methods: After Institutional Review Board approval, this prospective study was conducted enrolling children (weight range 7-40 kg) undergoing minor procedures who had indwelling central venous access for clinical indications. Infant and paediatric mainstream capnography masks were used according to patient body weight. Central venous blood was collected for analysis of PcvCO2 during capnography recording. Values for PcvCO2 and PexCO2 obtained from mainstream mask capnography monitoring were compared in individual patients. Results: Forty children were enrolled and analysed. All patients had an uneventful anaesthetic course and entered the PACU without respiratory compromise. The average and Standard Deviation (SD) of PcvCO2 were 47.5 (5.0) mmHg. Measurement error between PexCO2 at blood sampling was 6.1 (SD; 3.2) mmHg. When PcvCO2 >50 mmHg and PexCO2 >45 mmHg from the mask was used as the threshold for hypercapnia the sensitivity was 77%, specificity 96%, and Area Under the Curve (AUC) 0.866 at the time of blood sampling. Conclusion: Measurement error between PexCO2 and PcvCO2 was similar to known exhaled-arterial PCO2 difference (4-6 mmHg). We conclude that a mainstream mask capnography is a reliable method to assess hypoventilation and hypercapnia in non-intubated children.

Authors and Affiliations

Abhishek Karnwal, Makoto Nagoshi, Rica Morzov, Justin Hotz, Allan Cresencia, Sameh Nour, Paula Belson, Patrick Ross

Keywords

Related Articles

Serum Free T3 to Free T4 Ratio as a Useful Indicator for Differentiating Destruction Induced Thyrotoxicosis from Graves' Disease

Introduction: Thyrotoxicosis is a common disease encountered in Endocrine Outpatient Department (OPD). Two common causes of thyrotoxicosis are Destruction Induced Thyrotoxicosis (DIT) and Graves’ Disease (GD). Differenti...

Failed Back Surgery Syndrome: Evaluation with Magnetic Resonance Imaging

Introduction: Failed Back Surgery Syndrome (FBSS) is a generalized term used to describe varied spinal symptoms of patients who have had unsuccessful results after spinal surgery. The treatment of FBSS is challenging and...

Can Salivary Acetylcholinesterase be a Diagnostic Biomarker for Alzheimer?

Introduction: The loss of brain cholinergic activity is a key phenomenon in the biochemistry of Alzheimer's Disease (AD). Due to the specific biosynthesis of Acetylcholinesterase (AChE) of cholinergic neurons, the enzyme...

Point Matching Technique for Root Coverage Exposed by Visible Gingival Recession

ABSTRACT A new point matching technique as a viable and effective treatment option for coverage of root surface exposed by visible gingival recession was designed while avoiding the complications and complaints often ass...

Download PDF file
  • EP ID EP580947
  • DOI 10.7860/JCDR/2019/40550.12717
  • Views 93
  • Downloads 0

How To Cite

Abhishek Karnwal, Makoto Nagoshi, Rica Morzov, Justin Hotz, Allan Cresencia, Sameh Nour, Paula Belson, Patrick Ross (2019). Mainstream Capnography Correlates Well with Central Venous Carbon Dioxide Levels in Non-intubated Children in PACU. Journal of Clinical and Diagnostic Research, 13(3), 11-15. https://europub.co.uk./articles/-A-580947