Marginal fit of metal-free crown, observed in scanning electron microscope after three years in function

Journal Title: RSBO - Year 2009, Vol 6, Issue 2

Abstract

Introduction: Ceramics are considered an excellent choice as esthetic restorative material, but relevant questions like marginal fit require more attention in manufacturing than conventional systems. Objective: This work evaluated the marginal adaptation of an In-Ceram crown over a tooth that, after three years, had been indicated to extraction by orthodontics. Material and methods: The evaluation was by mean scanning electron microscope. Results and conclusion: It was found values of gaps between 157 and 390 μm, getting a statistic average considered greater than the accepted by literature.

Authors and Affiliations

Marcio BINDO, Rogério COSTA, Eduardo MORAIS, Moira LEÃO, Sávio SILVA

Keywords

Related Articles

Evaluation of two speeds applied to the Profile.04 in the endodontic retreatment time of Thermafille system

The aim of this study was to compare the time spent through the 0.04 ProFile system in the removal of the root fillings of the root canal in teeth obturated with the thermafill system. 30 tooths,divided in two groups hav...

Internal root resorption in the maxillary central incisor

Introduction: Internal root resorption is a chronic inflammatory process initiated within the pulp space with the loss of dentin. The clastic cells present in the pulp tissue trigger a progressive resorption phenomenon....

Epidemiology study of malocclusion children between 6 and 8 years old in city of Curitiba –Paraná

This study appraised 1550 children with ages varying from 6 to 8 years in the city of Curitiba, in order to determine the prevalence of malocclusion and its distribution according to the different ethnic groups. It was s...

Immediate loading of dental implants – case report

Introduction: A contemporary alternative to rehabilitate patients with partial or total loss of teeth is the immediate loading. Considering the evolution of surgical techniques, advances in diagnostic methods,wide biolog...

Periodontal disease and its influence on the metabolic control of diabetes

Introduction: Currently, it is accepted that the periodontal disease is more prevalent and severe in people with diabetes mellitus compared to non-diabetic people. On the other hand, patients with severe periodontitis ma...

Download PDF file
  • EP ID EP113291
  • DOI -
  • Views 173
  • Downloads 0

How To Cite

Marcio BINDO, Rogério COSTA, Eduardo MORAIS, Moira LEÃO, Sávio SILVA (2009). Marginal fit of metal-free crown, observed in scanning electron microscope after three years in function. RSBO, 6(2), 129-134. https://europub.co.uk./articles/-A-113291