Marginal fit of metal-free crown, observed in scanning electron microscope after three years in function

Journal Title: RSBO - Year 2009, Vol 6, Issue 2

Abstract

Introduction: Ceramics are considered an excellent choice as esthetic restorative material, but relevant questions like marginal fit require more attention in manufacturing than conventional systems. Objective: This work evaluated the marginal adaptation of an In-Ceram crown over a tooth that, after three years, had been indicated to extraction by orthodontics. Material and methods: The evaluation was by mean scanning electron microscope. Results and conclusion: It was found values of gaps between 157 and 390 μm, getting a statistic average considered greater than the accepted by literature.

Authors and Affiliations

Marcio BINDO, Rogério COSTA, Eduardo MORAIS, Moira LEÃO, Sávio SILVA

Keywords

Related Articles

Comparative study between formocresol and glutaraldehyde in pulpotomy – literature review

The pulps exposures caused by caries lesions or trauma, in deciduous teeth, frequently result in pulpotomy. Pulpotomy is the removal of the tissue that fills the camera pulp – that is to say, coronary pulp – and also th...

Radiographic analysis of prevalence of impacted third molars in the odontological office of the university – Centro Universitário Positivo

The occurrence of impacted third molars is a common situation in dental offices, consequently, a critical analysis is imperative for a correct diagnosis and treatment plan. Concerning this approach, the panoramic x-ray i...

Prevalence of dental trauma among children treated in the Pediatric Dentistry Clinic of the State University of Amazonas

Introduction: Dental trauma is an acute energy transmission to the tooth and to the supporting structures that may result in fracture, tooth dislocation, breaking or crushing of supporting tissues. Objective: This retros...

Treatment of traumatized teeth with incomplete apex – apexification

Introduction and objective: Two cases reports of traumatized teeth with incomplete apexes and no tooth fracture. Case report: In these cases, instrumentation should be performed with no pressure to the walls due to the d...

 Comparison of the sealing ability of different types of glass ionomer cements in temporary restoration

 Introduction: Glass ionomer cement has been used for temporary restoration; however, several formulations are available. Objective: The aim of this study was compare the linear leakage of different types of glass i...

Download PDF file
  • EP ID EP113291
  • DOI -
  • Views 197
  • Downloads 0

How To Cite

Marcio BINDO, Rogério COSTA, Eduardo MORAIS, Moira LEÃO, Sávio SILVA (2009). Marginal fit of metal-free crown, observed in scanning electron microscope after three years in function. RSBO, 6(2), 129-134. https://europub.co.uk./articles/-A-113291