Measurement of Free Versus Total Therapeutic Monoclonal Antibody in Pharmacokinetic Assessment is Modulated by Affinity, Incubation Time, and Bioanalytical Platform
Journal Title: The AAPS Journal - Year 2015, Vol 17, Issue 6
Abstract
Decisions about efficacy and safety of therapeutic proteins (TP) designed to target soluble ligands are made in part by their ex vivo quantification. Ligand binding assays (LBAs) are critical tools in measuring serum TP levels in pharmacokinetic, toxicokinetic, and pharmacodynamic studies. This study evaluated the impact of reagent antibody affinities, assay incubation times, and analytical platform on free or total TP quantitation. An ELISA-based LBA that measures monoclonal anti-sclerostin antibody (TPx) was used as the model system. To determine whether the method measures free or total TPx, the effects of Kon, Koff, and KD were determined. An 8:1 molar ratio of sclerostin (Scl) to TPx compared to a 1:1 molar ratio produced by rabbit polyclonal antibodies to TPx was required to achieve IC50, a measure of TPx interference effectiveness, making it unclear whether the ELISA truly measured free TPx. Kinetic analysis revealed that Scl had a rapid dissociation rate (Koff) from TPx and that capture and detection antibodies had significantly higher binding affinities (KD) to TPx. These kinetic limitations along with long ELISA incubation times lead to the higher molar ratios (8:1) required for achieving 50% inhibition of TPx. However, a microfluidic platform with the same reagent pairs required shorter incubations to achieve a lower Scl IC50 molar ratio (1:1). The findings from this study provide the bioanalytical community with a deeper understanding of how reagent and platform selection for LBAs can affect what a particular method measures, either free or total TP concentrations.
Authors and Affiliations
Jeffrey J. Talbot, Dominador Calamba, Melody Pai, Mark Ma, Theingi M. Thway
Population Pharmacokinetic Modeling of the Enterohepatic Recirculation of Fimasartan in Rats, Dogs, and Humans
The online version of this article (doi:10.1208/s12248-015-9764-2) contains supplementary material, which is available to authorized users.
Analytical Similarity Assessment in Biosimilar Studies
For assessment of biosimilarity, the US Food and Drug Administration (FDA) recommends a stepwise approach for obtaining the totality-of-the-evidence for demonstrating biosimilarity between a proposed biosimilar product a...
Lung microdialysis—A powerful tool for the determination of exogenous and endogenous compounds in the lower respiratory tract (mini-review)
In vivo measurement of concentrations of drugs and endogenous substances at the site of action has become a primary focus of research. In this context the minimal invasive microdialysis (MD) technique has been increasing...
A Novel Approach to Evaluate the Pharmacokinetic Biocomparability of a Monoclonal Antibody Derived from Two Different Cell Lines Using Simultaneous Crossover Design
A parallel study design with a large number of subjects has been a typical path for pharmacokinetic (PK) biocomparability assessment of biotherapeutics with long half-lives and immunogenic propensity, for example, monocl...
Indolealkylamines: Biotransformations and Potential Drug–Drug Interactions
Indolealkylamine (IAA) drugs are 5-hydroxytryptamine (5-HT or serotonin) analogs that mainly act on the serotonin system. Some IAAs are clinically utilized for antimigraine therapy, whereas other substances are notable a...