MEASUREMENT OF PERSONAL DOSE EQUIVALENT OF X AND GAMMA RADIATION BY RING DOSIMETER: RESULTS OF INTERCOMPARISON MEASUREMENTS

Journal Title: Medycyna Pracy - Year 2013, Vol 64, Issue 5

Abstract

Background: The aim of the study was to present the results of the interlaboratory comparisons for ring dosimeters and to confirm that the applied method is suitable for measuring the personal dose equivalent HP(0.07). In addition, calibration procedures used in dosimetric measurements in persons occupationally exposed to ionizing photon radiation X and γ were presented. Materials and Methods: Ring dosimeters made of flexible plastics with the diameter of approximately 20 mm, equipped with two thermoluminescence (TL) detectors type MTS-N, were the subject of interlaboratory comparisons. Irradiated detectors were red out using a new manual TLD's reader (FIMEL, France). All TLD exposures were done for validation of TLD readers and were performed using the reference X-ray and γ beams with the ISO rod phantom. The methodology of performed exposures corresponded with the methods applied by the European Radiation Dosimetry Group (EURADOS), the European organizer of interlaboratory comparisons. Results: The energy, dose and angular characteristics of the ring dosimeter allowed to elaborate the formula for estimating and verifying the personal dose equivalent HP(0.07). The test was performed to check and confirm the correctness of the estimated characteristics. The test results were satisfactory, and thus the readiness to implement TLD reader in the used method and to participate in interlaboratory comparisons was confirmed. Conclusions: According to the requirements of the Polish Centre for Accreditation, the laboratory was participating in the interlaboratory comparison organized by EURADOS in terms of the personal dose equivalent HP(0.07). The result of the comparison was satisfactory, therefore the correctness of the testing procedure was confirmed.

Authors and Affiliations

Małgorzata Adamowicz, Sylwia Papierz, Janusz Kacprzyk, Zbigniew Kamiński, Marek Zmyślony

Keywords

Related Articles

Guidelines for the use of the International Classification of Radiographs of Pneumoconioses of the International Labour Office (ILO): Substantial changes in the currrent edition

The International Classification of Radiographs of Pneumoconioses is the scheme worked out by the International Labour Office in Geneva (ILO), to register radiographic chest abnormalities in a well-ordered, reproducible...

RELATIONSHIPS BETWEEN WORK-FAMILY AND FAMILY-WORK CONFLICTS AND HEALTH OF NURSES - BUFFERING EFFECTS OF SOCIAL SUPPORT

Background: The aim of the study was to investigate the relationships between work-family conflict (WFC), family-work conflict (FWC) and health, as well as the moderating effect of social support. The study was based on...

Guidelines for the preventive health care of hairdressing apprentices

Hairdressing is one of the most developing branch of the service industry in Poland. Providing representatives of this occupational group with preventive health care services it should be remembered that they are at risk...

POZIOM NATĘŻENIA GŁOSU WYKŁADOWCÓW - WYNIKI BADAŃ PRZEPROWADZONYCH PODCZAS WYKŁADÓW

Wprowadzenie: Osoby wykorzystujące głos zawodowo (m.in. wykładowcy) mówią z różnym poziomem natężenia głosu. Regulują je świadomie (np. uwypuklając znaczenie fragmentów przekazu) i nieświadomie (np. w obecności wysokiego...

Health effect of chronic exposure to carbon disulfide (CS2) on women employed in viscose industry

Many women are exposed to carbon disulfide (CS2) hazards at work every day. Working with CS2 may cause some women to experience abnormalities in their reproductive health. Until now obtained data is generally concentrate...

Download PDF file
  • EP ID EP146948
  • DOI http://dx.doi.org/10.13075/mp.5893.2013.0055
  • Views 167
  • Downloads 0

How To Cite

Małgorzata Adamowicz, Sylwia Papierz, Janusz Kacprzyk, Zbigniew Kamiński, Marek Zmyślony (2013). MEASUREMENT OF PERSONAL DOSE EQUIVALENT OF X AND GAMMA RADIATION BY RING DOSIMETER: RESULTS OF INTERCOMPARISON MEASUREMENTS. Medycyna Pracy, 64(5), 631-637. https://europub.co.uk./articles/-A-146948