Mechanical Fatigue Analysis Comparing Two Locking Plates in a Metaphyseal Fracture Model of the Distal Ulna

Journal Title: Journal of Musculoskeletal Disorders and Treatment - Year 2016, Vol 2, Issue 3

Abstract

The purpose of the study was to test the mechanical fatigue properties (fatigue limit and fatigue strength) of two locking plates designed for the distal ulna. Distal Ulna Plate 2.5 (Medartis, Basel, Switzerland) and 2.0 mm LCP Distal Ulna Plate (DePuySynthes, West Chester (PA), USA) were used. A metaphyseal fracture situation was chosen (AO 23-A1.3). Six plate-screw constructs of each design were mounted on custom made fixtures using a Sawbone's 3D ulna model. Testing was performed on monoaxial material testing machines. Endpoints were fatigue strength (load) and fatigue limit (cycles) when the sample fails. Initial load was set at Fmax 10 N. Sinusoidal loading was carried out at 4 Hz. After 50'000 cycles load was increased by 15% and again by 15% after each additional 10'000 cycles. 2.5 mm plates showed median fatigue strength of 40.5 N (range 5.3) and median fatigue limit of 141'307 cycles (range 5'436). 2.0 mm plates 13.2 N (range 5.2) and 67'287 cycles (range 28'718) respectively. Distal Ulna Plate 2.5 showed better mechanical properties.

Authors and Affiliations

Keywords

Related Articles

Developmental Insights into Osteoarthritis Increase the Applicability of New Animal Models

Osteoarthritis (OA) is an increasingly common degenerative joint condition, estimated to affect more than 100 million people worldwide and more than 40% of people over 70 years of age. There is currently no pharmacologic...

The Chondral Tissue and PRP. Theory to Support the Use

The hyaline cartilage structure is very complex, with few cells, and without blood and lymphatic vessels or nerves. This makes the healing potential very limited. Knee cartilage injuries are very common, and its treatmen...

Medial Epicondylitis and Medial Elbow Pain Syndrome: Current Treatment Strategies

Medial elbow pain is a common complaint in the active population. The most frequent muscular or tendinous condition to cause medial elbow pain is Medial Epicondylitis (ME). The disorder is classically described as "Golfe...

Recovery of Functional Diaphragmatic Activity following Complicated Unilateral or Bilateral Phrenic Nerve Injuries using Multi-Modality Treatment

Background:Diaphragmatic paralysis may occur as a result of dysfunction in the central nervous system or phrenic nerves leading to inspiratory muscle weakness and a restrictive ventilatory deficit. Phrenic nerve reconstr...

Outcomes of Non-operative Management of Deep Gluteal Syndrome - A Case Series of Six Patients

Introduction:An increased understanding of posterior hip anatomy and biomechanics has led to advances in the diagnosis and management of Deep Gluteal Syndrome (DGS). Currently, there is limited information detailing the...

Download PDF file
  • EP ID EP348042
  • DOI 10.23937/2572-3243.1510018
  • Views 127
  • Downloads 0

How To Cite

(2016). Mechanical Fatigue Analysis Comparing Two Locking Plates in a Metaphyseal Fracture Model of the Distal Ulna. Journal of Musculoskeletal Disorders and Treatment, 2(3), 1-4. https://europub.co.uk./articles/-A-348042