Abstract

The purpose of the study was to test the mechanical fatigue properties (fatigue limit and fatigue strength) of two locking plates designed for the distal ulna. Distal Ulna Plate 2.5 (Medartis, Basel, Switzerland) and 2.0 mm LCP Distal Ulna Plate (DePuySynthes, West Chester (PA), USA) were used. A metaphyseal fracture situation was chosen (AO 23-A1.3). Six plate-screw constructs of each design were mounted on custom made fixtures using a Sawbone's 3D ulna model. Testing was performed on monoaxial material testing machines. Endpoints were fatigue strength (load) and fatigue limit (cycles) when the sample fails. Initial load was set at Fmax 10 N. Sinusoidal loading was carried out at 4 Hz. After 50'000 cycles load was increased by 15% and again by 15% after each additional 10'000 cycles. 2.5 mm plates showed median fatigue strength of 40.5 N (range 5.3) and median fatigue limit of 141'307 cycles (range 5'436). 2.0 mm plates 13.2 N (range 5.2) and 67'287 cycles (range 28'718) respectively. Distal Ulna Plate 2.5 showed better mechanical properties.

Authors and Affiliations

Keywords

Related Articles

Bone Mineral Density Measured by Quantitative Computed Tomography in Pre-pubertal/Early Pubertal Children with Hypovitaminosis D

Background:Clinically significant vitamin D deficiency is associated with decreased bone mineral density (BMD) and increased fracture risk in adults. A similar association is suggested to be present in children. In this...

Survey of Pain Therapies in Marfan Syndrome

Objective Pain in Marfan syndrome is common, although frequently under diagnosed and undertreated. Few studies have investigated the treatment of pain symptoms in Marfan syndrome and no study has reported on the use of o...

The Effects of an Audible Low Frequency Acoustic Waveform on Osteoarthritis: A Pilot Study

Objective:The purpose of this pilot study was to investigate the effects of an audible low frequency acoustic waveform on pain and range of motion (ROM) for patients with osteoarthritis (OA). Methods:Twenty one adults w...

Regenerative Therapy in Osteoarthritis of the Knee

Osteoarthritis (OA) is the most common joint disorder in the world. It commonly affects the knee and current treatment options are limited, focusing mainly on symptom relief. It is now known that OA is the result of both...

Immune-mediated Mechanisms and Immunotherapy of Duchenne Muscular Dystrophy

The immune response is a critical mechanism for dystrophic muscle pathology and muscle wasting in Duchenne Muscular Dystrophy (DMD). The inflammatory processes are supposed to associate with activation of the innate immu...

Download PDF file
  • EP ID EP348042
  • DOI 10.23937/2572-3243.1510018
  • Views 115
  • Downloads 0

How To Cite

(2016). Mechanical Fatigue Analysis Comparing Two Locking Plates in a Metaphyseal Fracture Model of the Distal Ulna. Journal of Musculoskeletal Disorders and Treatment, 2(3), 1-4. https://europub.co.uk./articles/-A-348042