Mitigation of commutation faults in HVDC system

Journal Title: International Journal of Engineering and Science Invention - Year 2017, Vol 6, Issue 10

Abstract

To transfer large amount of direct current power having high amplitude voltage over long distance, high voltage direct current (HVDC) transmission system is used. This system was introduced 60 year ago and now it is widely used all over the world. Some examples of HVDC systems are following; Voltage-SourcedConverter (VSC), current commutated converter (CCC) and line commutated converter (LCC) dependent HVDC techniques.VSC method used for multi-terminal Direct Current grid, but line commutated direct current method performs better as compare to VSC in broad distance large amount of power transmission due to its efficiency. When voltage is reduced to 10% to 15% in LCC HVDC system the commutation failure occurs. The LCC HVDC system is having better performance in comparison to others so the analysis is done on this system to mitigate the commutation failure which is very frequent event that occurs in the this system. The DC fault is having less effect on commutation as compare to the AC single and three phase fault. During DC fault only the distortion is occurring which is minimized with the help of DC filter. During AC faults the commutation failure occurs which is minimized using IGBT capacitor circuit. The comparison of systems with and without faults is done and it is concluded that the AC faults are the main reason of commutation failure and mitigation is done using IGBT capacitor circuit.

Authors and Affiliations

Kamaljeet Kaur, Navneet Singh Bhangu

Keywords

Related Articles

Value Stream Mapping: Literature Review And Implementation For An Assembly Line

ean manufacturing initiative is being followed by various organizations in the recent years which mainly focus on improving the efficiency of operations by eliminating and reducing wastes. A major activity in the journey...

Study of the Compressive Strength Behaviour of Steel Fibre Reinforced Concrete Using Various Percentage of Steel Fibre

The objective of this Research investigation was to study the compressive strength behavior of Steel Fibre Reinforced Concrete (SFRC) using Round straight fibres with aspect ratio of 75 .Specimens were cast without fibre...

Heat Reduction in Car Cabin by Using Nonconventional Source of Energy

The refrigerating units currently used in road transport vehicle are of Vapour Compression Refrigeration system (VCRS). This system utilizes power from the engine shaft as the input power to drive the compressor of the r...

Information Pre-Rendering For Categorization Using Waikato Environment For Knowledge Analysis

Pattern measurements through incalculable examinations delineate that there is an exponential development of information shape terabytes to petabytes and past on the planet. This reality brings into point of view the evi...

Prediction of Defects in Axle Production Using Monte-Carlo Simulation

The automotive industry in India is one of the largest in the world. India is also a prominent auto exporter and has strong export growth expectations for the near future. Like companies in all sectors of manufacturing,...

Download PDF file
  • EP ID EP403429
  • DOI -
  • Views 68
  • Downloads 0

How To Cite

Kamaljeet Kaur, Navneet Singh Bhangu (2017). Mitigation of commutation faults in HVDC system. International Journal of Engineering and Science Invention, 6(10), 79-88. https://europub.co.uk./articles/-A-403429