Modified Multiphase Level Set Image Segmentation Search for Energy Formulation with Bias Correction
Journal Title: UNKNOWN - Year 2013, Vol 2, Issue 9
Abstract
Level set methods are a popular way to solve the image segmentation problem. The solution contour is found by solving an optimization problem where a cost functional is minimized. The purpose of this paper is the level set approach to simultaneous tissue segmentation and bias correction of Magnetic Resonance Imaging (MRI) images. A modified level set approach to joint segmentation and bias correction of images with intensity in homogeneity. A sliding window is used to transform the gradient intensity domain to another domain, where the distribution overlap between different tissues is significantly suppressed. Tissue segmentation and bias correction are simultaneously achieved via a multiphase level set evolution process. The proposed methods are very robust to initialization, and are directly compatible with any type of level set implementation. Experiments on images of various modalities demonstrated the superior performance over state-of-the-art methods.
General Implementation and Calculation of 5s Activity in any Organization
This paper is a proposal to do calculation of 5S activities and to do improvement at weak points of 5s system with the help of allotted rating and graph plotted.
Emotional Intelligence and Sociometric Scores of Elementary School Children
The present study was undertaken with a view to examine the relation between emotional intelligence and sociometric scores of elementary school children. The study sample consisted of 200 children (101 boys and 99 girls)...
Higher Mathematics Sign Language Interpreter
One of the important problems observed in society is that the deaf mutes are finding it hard to cope up with the fast growing technology. The aim of proposed topic is to introduce new sign language gestures for higher ma...
Effectiveness of Manual Mobilization with Movement on Pain and Strength in Adults with Chronic Lateral Epicondylitis
Objective: Tennis elbow is an inflammatory condition of the common extensor origin over the lateral epicondyle. This condition does not affect tennis players only. It often follows an injury or sudden contraction of the...
Assessment of Chlorination Efficiency and Quality of Municipal Drinking Water in Gwalior City, Madhya Pradesh, India
The quality of drinking water at the point of delivery to the consumer is crucial in safeguarding people’s health. This study was carried out to study effectiveness of chlorination throughout drinking water distribution...