Monitoring of indoor air in the apartment

Abstract

Apartment occupants have a major impact on indoor air quality. Indoor air pollution includes water vapour, carbon dioxide and other gases due to respiration and bodily odours. Negative impact they have from brought in by clothing and footwear or becomes whirled up from floors, carpets etc. In this article presents the experimental measurement of indoor air quality, mainly concentration of carbon dioxide, air temperature and relative humidity. Indoor air parameters are recorded during 24 hour per every day the all week. Measurements take place was exercised in these rooms: living room, children rooms, kitchen, bathroom and corridor. During the measurements the investigated room was occupied by different persons regarding the sex, age and weight. Measurements were carried out during a sedentary work using computer and other home works. The main result of this research is the monitoring of indoor air in the apartment for, calculation of uncontrolled ventilation of rooms, which is caused leaks through building structures. The resulting values, calculated of uncontrolled ventilation rate, it will be possible to use for in determining the needed ventilation rate for the achieving needed air quality. From The graphic illustrations concentration of carbon dioxide, is possible observe real course the concentration of carbon dioxide in the apartments during their use. From measurements is possible conclude, whether in the apartment, during its use, occur there the over limit values of pollutants.

Authors and Affiliations

P. Kapalo, F. Domnita, C. Bacotiu, O. Voznyak

Keywords

Related Articles

MODELLING OF REINFORCED CONCRETE BEAMS WITH PRETENSIONED FRP REINFORCEMENT

Traditional building materials are regularly improved, finding new operational characteristics and complementing the quality of technical parameters. For a long time and now as reinforcement of reinforced concrete elemen...

Моделювання процесів теплообміну в топках водотрубних котлів дКВР(де)-10/14

Тhe results of a numerical study of heat transfer in water-tube boiler DKVR(DE)-10/14 furnace are provided. The geometric model of the inner cavity of furnaces and burners is constructed with help of boiler and burner GM...

ЕКСПЕРИМЕНТАЛЬНІ ДОСЛІДЖЕННЯ ДЕФОРМАТИВНОСТІ І МІЦНОСТІ ПОПЕРЕДНЬО НАПРУЖЕНОЇ ЗБІРНО-МОНОЛІТНОЇ БАЛКИ ПРОГОНОВОЇ БУДОВИ ПРОЛЬОТОМ 12 М

The paper presents only some problems of design and constraction of the bridge. The active provides the results of the research out composite muilti-span prestressed reinforced concrete beam for time building bridges. Co...

МІЦНІСТЬ ЗАЛІЗОБЕТОННИХ БАЛОК, ПІДСИЛЕНИХ ПОПЕРЕДНЬО НАПРУЖЕНОЮ АРМАТУРОЮ

This article describes strengthening normal cross-section of reinforced concrete beams with prestressed reinforcement under load. The samples of RC beam with 2100 mm. length, 100 mm width, and 200 mm height was tested. A...

Теплова ефективність комбінованої геліосистеми в режимі протоку за південно-східного та південно-західного напрямку орієнтації

Solar radiation - is an inexhaustible source of renewable energy. Using solar energy is sufficiently promising to improve the environmental situation, reducing of consumption of fossil fuels, as well as for household and...

Download PDF file
  • EP ID EP230918
  • DOI -
  • Views 86
  • Downloads 0

How To Cite

P. Kapalo, F. Domnita, C. Bacotiu, O. Voznyak (2016). Monitoring of indoor air in the apartment. Вісник Національного університету "Львівська політехніка". Серія "Теорія та практика будівництва", 0(844), 272-277. https://europub.co.uk./articles/-A-230918