Morphological characteristics of the celiac-mesenteric trunk
Journal Title: Revista de Medicină Militară - Year 2019, Vol 0, Issue 2
Abstract
The present paper describes the morphological characteristics of 12 celiac-mesenteric trunk cases highlighted by angiography-computed tomography (CT), characteristics met only in male cases (1.82% of the cases). In relation to the vertebral column, the origin of the trunk was found in the upper half of the L1 vertebra – intervertebral disk between L1 and L2 vertebrae. At the level of its origin from the aorta, the celiac-mesenteric trunk had an external diameter with values ranging from 8.7-13.4 mm, the aortic ostium of the celiac-mesenteric had a vertical diameter ranging from 8.8 to 13.1mm, the horizontal diameter values ranging from 8.8 to 11.2mm. At the level of its origin, the celiac-mesenteric trunk and the aortic wall had an angle with values ranging from 30.0o to 90.2o. The length of the celiac-mesenteric trunk had values ranging from 21.8 to 42.5 mm, most frequently met values were ranging from 30.7 to 33.5mm. At the level of its bifurcation, the celiac-mesenteric trunk had an angle with values ranging from 82.2 to 120,7, most frequently met values were over 90o. The celiac trunk resulted from the celiac-mesenteric bifurcation had an exterior diameter of 6.2 – 10.2 mm, values that in relation to exterior diameter the celiac-mesenteric originated, it represented 65.57 – 92.47% of its external diameter. The celiac trunk up to the end of its ramification had a length with values ranging from 6.3 to 16.8 mm. In all cases being a hepatosplenic trunk, the left gastric aorta originated in the abdominal aorta in 10 cases (83,3% of the cases) and in the other 2 cases, the left gastric aorta originated in one case under the end bifurcation of the celiac trunk whereas the other case in the celiac-mesenteric trunk, before its end bifurcation. The superior mesenteric artery resulting from the ramification of the celiac-mesenteric trunk had an external diameter with values ranging from 4.4 to 8.5 mm that represented 44.44 – 85.06% of the external diameter of the celiac-mesenteric trunk.
Authors and Affiliations
P Bordei, R Baz, Cristian R. Jecan, V Ardeleanu
About health, with hope
-
TOT versus TVT – mesh surgical treatment in stress urinary incontinence
Introduction: Stress urinary incontinence is a highly debilitating condition, with an important impact over the quality of life. When the conservative treatment fails, the surgical treatment is a viable solution. Minimal...
Tumor markers in gastroenterology: useful or useless
-
Romanian sanitary system assisted by knowledge management
As the medical sciences advances, so does the volume of information which becomes more and more consistent. The health care system is one of the most complex systems encountered in our society. Today, knowledge managemen...
Diagnostic difficulties in c-kit negative gastrointestinal stromal tumors: report of 4 cases
Introduction: The gastrointestinal stromal tumors (GIST) are dominated by KIT and PDGFRA mutation. The immunohistochemical detection of CD117, a protein express by KIT gene, is essential for the diagnosis and those that...