MORPHOMETRİC CHARACTERISTICS OF HUMAN VERTEBRAL COLUMN WHICH HAS NUMERICAL VARİATİON

Journal Title: Journal of Turkish Spinal Surgery - Year 2000, Vol 11, Issue 4

Abstract

Recent developments in surgical interventions and increasing popularity of using implants in lovver thoracal and lumbar vertebrae have necessitated more detailed knovvledge of anatomical and morphometric characteristics of these structures. Here we present a 22-year-old male skeleton that has 25 presacral vertebrae (PSV). The sceleton has thoraco-lumbar (TL) vertebrae with a numerical variation of vertebral column, and we discuss morphometric characteristics of his lovver thoracal and lumbar vertebrae.

Authors and Affiliations

Mehmet ÇİMEN, Haşan ELDEN, Sıtkı PERÇİN

Keywords

Related Articles

IS CUFF LEAK TEST VALID IN MANAGING DIFFICULT EXTUBATION AFTER CERVICAL SPINE FUSION OPERATION?

We report a 38 year old male patient underwent basilar invagination and Arnold-Chiari type I malformation. Although he has effective spontaneous ventilation, he is fully awake, there were no signs of laryngeal edema, and...

AN OVERVIEW OF ADULT SPINAL DEFORMITY

INTRODUCTION The evaluation and treatment of adult spinal deformity remains a challenging clinical entity. Many factors must be analyzed to help decide the best treatment plan for these patients ranging from conserva...

USE OF ALLOGRAFT BONE CHIPS IN POSTERÎOR SPİNAL SURGERY

For most of the spinal disorders posterior instrumentation and fusion is a treatment of choice. But instrumentation is oniy a temporary stabilization method for obtaining fusion of the affected vertebrae, and instrument...

THE COMPARISON OF THE FUSION RATE İN ANTERIOR INTERBODY FUSION BETVVEEN NONINFECTIOUS AND INFECTIOUS DISEASES OF THE SPINE

Three hundred and twenty six cases with spinal diseases (209 noninfectious and 117 infectious) were treated by anterior interbody fusion. Preoperative plain radiography vvas done and the periodic plain radiography was...

CLINICAL İMPORTANCE OF THE MİNİMAL CANCELLOUS DIAMETER OF LOWER THORACIC AND LUMBAR VERTEBRAL PEDICLES

Transpedicular spinal fixatiorı is a widely used method in vertebrai surgery, but it suffers from complications due to mismatches betvveen the screw and pedicle. Therefore, information of minimal canceiious (MCD) and min...

Download PDF file
  • EP ID EP676429
  • DOI -
  • Views 128
  • Downloads 0

How To Cite

Mehmet ÇİMEN, Haşan ELDEN, Sıtkı PERÇİN (2000). MORPHOMETRİC CHARACTERISTICS OF HUMAN VERTEBRAL COLUMN WHICH HAS NUMERICAL VARİATİON. Journal of Turkish Spinal Surgery, 11(4), -. https://europub.co.uk./articles/-A-676429