NaI(Tl) Scintillator's Response Functions for Point-like and Distributed Gamma-ray Sources

Abstract

The response functions of a NaI(Tl) detectors have been estimated using Monte Carlo methods. Response functions were calculated for monoenergetic photon sources (0.05 to 3 MeV). Responses were calculated for point-like sources and for sources distributed in Portland cement cylinders. Calculated responses were used to estimate the detector efficiency for pointlike and distributed sources. Samples of cylindrical Portland cement were prepared and exposed to the photoneutron field produced by a 15 MV linac used for radiotherapy. Short half-life radioisotopes were induced and the activity was determined by measuring the pulse-height spectra with a NaI(Tl) g-ray spectrometer that was calibrated using point-like sources. Instead of doing corrections due to differences between the geometry, material and solid angle of point-like sources used for calibration, and the Portland cement cylinders, the detection efficiency was determined using the ratio between the efficiencies for the point-like and the distributed sources estimated with the Monte Carlo calculations, and the activity of the induced isotopes in cement was obtained.

Authors and Affiliations

H. R. Vega-Carrillo, J. I. Benites-Rengifo, V. M. Hernandez-Davila, J. M. Ortiz-Rodriguez, H. A. De Leon-Martínez

Keywords

Related Articles

Radon Exhalation from Industrial Residues as Suitable Additives for Building Materials

Radon exhalation from phosphogypsum (PG) and red mud (RM) samples are of environmental concern. The study is oriented to evaluate by different nuclear techniques, industrial materials cumulated in sites at Morón (PG) and...

On the Equivalent Sources and Geometric Factor Calculation for a Circular Detection Case

In all absolute measurements of the intensity of the radioactive materials and calibration of the detectors, it is essential the knowledge of the geometric efficiency. This work describes how to obtain the sources with d...

Cluster Radioactivity in 127I

Using the preformation cluster model of Gupta and collaborators we have studied all the possible cluster decay modes of 127 I. The calculated half-lives are compared with recently measured lower limits of cluster decay h...

Jung’s Theorem Applied in Nuclear Track Methodology

Nuclear track density provides accelerator beam imaging and diagnostic employing CR-39 passive detectors. Counting charged particles related tracks by automated reading systems depend on the accuracy of microscope field...

Analysis of the Energy Deposit in the Air by Radiation of Alpha Particles Emitted by the Water of a Spring Through the Geant4 Software

This work presents the development of an analysis of the potential radiological risk generated by alpha particles emitted by radon-222, content in a spring water, for the population that usually swims in the place and fo...

Download PDF file
  • EP ID EP594932
  • DOI 10.15415/jnp.2016.41013
  • Views 229
  • Downloads 0

How To Cite

H. R. Vega-Carrillo, J. I. Benites-Rengifo, V. M. Hernandez-Davila, J. M. Ortiz-Rodriguez, H. A. De Leon-Martínez (2016). NaI(Tl) Scintillator's Response Functions for Point-like and Distributed Gamma-ray Sources. Journal of Nuclear Physics, Material Sciences, Radiation and Applications, 4(1), 129-137. https://europub.co.uk./articles/-A-594932