Abstract

 The following case study is the result of the project work and research done by me at one of the major plant in AP. The case study is of a medium pressure water pump which had developed high vibrations. The causes of vibrations were identified using latest non destructive testing tools and corrective measures were implemented. The condition of the pump after the correction was checked and was found within acceptable healthy condition therefore pump was put to use.

Authors and Affiliations

Aditya U. Ganapathy1 , K. Sainath

Keywords

Related Articles

 Fabrication and Testing of Natural Fiber Reinforced Hybrid Composites Banana/Pineapple

 Work has been carried out to investigate the flexural properties of composites made by reinforcing banana and pineapple as the new natural fibers into epoxy resin matrix. The natural fibers were extracted by rettin...

Black Hole Detection in AODV Using Hexagonal Encryption in Manet’s

In MANETs (mobile ad hoc network), security is common problem and lack of issues in MANET network. When comparing to wired network, MANETs are harmed to security attacks due to the scarcity of a trusted central...

 Analysis of Conditions in Boundary Lubrications Using Bearing Materials

 In order to clearly establish the tribological potential of these alloys as bearing materials, the tribological parameters of the RAR Zn-Al alloys are compared to parameters of the CuPb15Sn8 lead-tin bronze, as a w...

Comparison of Spatial Interpolation Techniques - A Case Study of Anantnag District J&K, India

Groundwater is used for a variety of purposes, including irrigation, industrial, drinking, and manufacturing. Assessment and mapping of quality of groundwater is an important because the physical and chemical characteris...

 Simulation of a Two Stage High Power Factor Driver for White Power Led

 In this paper, an integrated double buck–boost (IDBB) converter is proposed as a high-power-factor offline power supply for power-LED lamps. The IDBB converter features just one controlled switch and two inductors...