Increasing Safety of the Tests Carried Out in Laboratories by Using Electronic Devices

Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2015, Vol 39, Issue 39

Abstract

 The ability of the circuit breakers to interrupt the electrical current in circuits with capacitive load it is tested and verified in testing laboratories. During the test, the capacitive type of load impedance simulates an overhead line or an underground cable that works with no load impedance. The transient behaviour which appears at the opening of electric circuits having capacitive load impedance can determine the appearance of some dangerous over-voltages for line, cables and equipments. After testing, at the circuit interruption, it is possible to be residual electrical charge on capacitors. This endangers the lives of people who configures the test scheme. The paper describes a device that monitors the voltage on the capacitors that are connected to busbars and which alerts the staff about the presence of electric charges remaining at the end of the test. A referral unit is mounted near the bars to that are connected capacitors, while warning unit is mounted in the place where can be observed by personnel that configure the test schemes. Two variants of the device are presented. The results, obtained with the device during carrying out tests, both in the laboratory and in operation, are presented into the final section of the paper.

Authors and Affiliations

Marinel Popescu

Keywords

Related Articles

THE STUDY OF THE AUTOMATIC SYSTEM FOR THE SEALED COCKPITS AIRFLOW REGULATION USING INDIRECTLY ACTION AIRFLOW REGULATORS

The paper presents the mathematical model of an automatic system for the sealed cabin airflow regulation using indirectly action airflow regulator. The goal of this Automatic Regulation System (ARS) is to constantly prov...

 Improving Efficiency of DWT Analysis through Faster Interpolation Methods and Multithreading Techniques

 The paper deals with techniques to accelerate the DWT power quality analysis. A brief description of a nonspline interpolation schematic is provided firstly. It is used for the evaluation of the first components...

The Analysis of Biphasic Short Circuit Regimes to Doubly-fed Induction Generators Connected to a Power System

The paper presents analysis of the biphasic short circuit regimes at the terminals of doubly fed induction generator connected to the national power system of the Republic of Moldova. Research related to connecting wind...

 Estimation of the Heat Cumulated Inside a Wall with Cylindrical Symmetry

 The issue of mathematical modeling in order to simulate physical processes or physical systems, permanently preoccupy a significant number of researchers. The sustained efforts being made in this direction are dete...

Automatic Sorting and Handling Station Actuated by Pneumatic Drive

The main path through which technical progress contributes to increasing work productivity is the automation of manufacturing processes. Applications based on robotic handling solve many problems in different areas, espe...

Download PDF file
  • EP ID EP90439
  • DOI -
  • Views 187
  • Downloads 0

How To Cite

Marinel Popescu (2015).  Increasing Safety of the Tests Carried Out in Laboratories by Using Electronic Devices. ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica, 39(39), 170-175. https://europub.co.uk./articles/-A-90439