Increasing Safety of the Tests Carried Out in Laboratories by Using Electronic Devices

Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2015, Vol 39, Issue 39

Abstract

 The ability of the circuit breakers to interrupt the electrical current in circuits with capacitive load it is tested and verified in testing laboratories. During the test, the capacitive type of load impedance simulates an overhead line or an underground cable that works with no load impedance. The transient behaviour which appears at the opening of electric circuits having capacitive load impedance can determine the appearance of some dangerous over-voltages for line, cables and equipments. After testing, at the circuit interruption, it is possible to be residual electrical charge on capacitors. This endangers the lives of people who configures the test scheme. The paper describes a device that monitors the voltage on the capacitors that are connected to busbars and which alerts the staff about the presence of electric charges remaining at the end of the test. A referral unit is mounted near the bars to that are connected capacitors, while warning unit is mounted in the place where can be observed by personnel that configure the test schemes. Two variants of the device are presented. The results, obtained with the device during carrying out tests, both in the laboratory and in operation, are presented into the final section of the paper.

Authors and Affiliations

Marinel Popescu

Keywords

Related Articles

REMOTE MONITORING SYSTEM OF THE TEMPERATURE OF DETACHABLE CONTACTS FROM ELECTRIC CELLS

This paper refers to a remote monitoring system of electric contacts with intense currents for eliminating the malfunctions due to imperfect contact and for increasing the security in electrical supply. Most electrical...

Digital Control for the Air Pressure with Multi-Characteristics Selection

The paper deals with a preparatory research stage for controlling the air pressure inside a small tank by various characteristics and algorithms. Basic elements both for the hardware design and for the software support a...

PARASITIC CAPACITANCE CANCELLATION FOR EMI FILTERS WITH AN EMBEDDED GROUND LAYER

Planar structures are often used in the construction of different equipment due to their many advantages like reducing the magnetic profiles, lower leakage inductance, lower HF losses in the windings and improving therma...

APPLICATION OF FIBER OPTIC INTEGRATED FABRYPEROT INTERFEROMETER FOR NON ELECTRIC QUANTITIES MEASUREMENT IN ELECTRICAL ENGINEERING

The non-electric quantities measurement technologies widely used in the present technique are based on conventional technologies known for many years, which lead to reliable and reproducible results. With a view to measu...

MODELLING OF ELECTROMECHANICAL CONVERTERS OF TRACTION USED ON ELECTRIC LOCOMOTIVES

The paper begins by presenting basic electrical diagrams of the main types of electric locomotives (with chopper and DC motors or with rectifiers and DC motors or with VVVF and induction motors IM or with self-controlled...

Download PDF file
  • EP ID EP90439
  • DOI -
  • Views 181
  • Downloads 0

How To Cite

Marinel Popescu (2015).  Increasing Safety of the Tests Carried Out in Laboratories by Using Electronic Devices. ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica, 39(39), 170-175. https://europub.co.uk./articles/-A-90439