MEASUREMENT OF INTERNAL CONVERSION COEFFICIENT Of 280kev γ – RAYS IN 203Hg

Abstract

 The measurement of the internal conversion coefficient of 280keV γ – ray in 203HG have been investigated by means of calibrated 2ʺ x 2ʺ NaI(Tl)(scintillation detector which is sodium iodide activated with small amount of thallium) γ – rays spectrometer, using the standard γ – rays sources Co67 and Ba133 as shown in Table(1), and prepared a source of Hg203 from Hg203Cl2. It have been used some heavy element Au198 isotope Ti81[3, 6, 9, 12,13, 15]. The total internal conversion coefficient of a γ – ray may be calculated by taking the ratio of the number of detected X – ray to the γ – ray, Equation (14). In this workit have been discussed some important γ – ray interaction processes like photoelectric effect, Compton scattering and pair production etc. through which gamma ray interact with matter and get absorbed in it[1,2,16]. The measured value of internal conversion coefficient of 280KeV γ – ray in Hg203 at various source detector distances in centimeters (0.0, 3.2, and 4.2) which gives internal conversion coefficient (α) 0.230, 0.179 and 0.187 respectively. The average internal conversion coefficient α, of 280 keV γ – ray in Hg203is 0.2. By comparingthe measurement results with the standard value, it had been found that the measured values of internal coefficient of 280 KeVγ – ray in 203Hg was independent of source detector distance which was obvious and came out to be 0.20. Our experiment finding was in good agreement with the earlier reported value as 0.20.

Authors and Affiliations

Zafaran Abdul Fattah

Keywords

Related Articles

PRIVATE BANKS’ ATMS EFFICIENCY AT GROUND ZERO: A CASE STUDY OF ALLAHABAD

The technological investment done by Private Banks especially in installing cash dispensing machines, i.e. ATMs in India, had also forced public sector banks to update themselves, as their competitors; gone are the days...

 EFFICIENT LIFTING-BASED FORWARD AND INVERSE DWT BASED ON VLSI ARCHITECTURE

 The wavelet transform is denoted by ‘WT’ gained wide-ranging approval in processing signal and in compressing image. A 2D analysis must be implemented to use WT for processing the image. Such powerful signal analy...

EFFECT OF IDOLS IMMERSION ON ANTHROPOGENIC INFLUENCED RITUAL PONDS WATER QUALITY AT HOLY CITY VARANASI

Many ponds of holy city Varanasi are polluted by anthropogenic activities. This is due to improper management of public and private sector. There is some religious importance of ponds in Varanasi. The concept is based o...

PERFORMANCE OF MATHEMATICAL MODELING OF PHOT OVOLTAIC MODULE WITH SIMULINK BUCK - BOOST CONVERTER

Photovoltaic systems require interfacing power converters between the PV arrays and the buck - boost converter . In this paper is proposes the modeling, design and simulation of photovoltaic solar cell model consi...

 APPROXIMATE SOLUTIONS FOR PERTURBED MEASURE DIFFERENTIAL EQUATIONS WITH MAXIMA

 In this paper, we study an approximation of the solutions for perturbed abstract measure differential equations with maxima via hybrid fixed point theorem of Dhage [ B.C.Dhage, on some nonlinear alternatives of Ler...

Download PDF file
  • EP ID EP154261
  • DOI 10.5281/zenodo.56997
  • Views 85
  • Downloads 0

How To Cite

Zafaran Abdul Fattah (30).  MEASUREMENT OF INTERNAL CONVERSION COEFFICIENT Of 280kev γ – RAYS IN 203Hg. International Journal of Engineering Sciences & Research Technology, 5(7), 403-417. https://europub.co.uk./articles/-A-154261