Variation of Performance of Refrigeration System at different Temperature
Journal Title: International Journal of Engineering Sciences & Research Technology - Year 30, Vol 3, Issue 7
Abstract
R143a and R152a) selected to replace R12 in a vapour compression refrigeration system were investigated experimentally and compared. The performance in term of coefficient of performance (COP), refrigerating capacity (RC), and compressor work (We) were evaluated for the investigated refrigerants at various evaporating and condensing temperatures. The system performance increases as the evaporating temperature increases, but reduces as the condensing temperature increases. The results obtained showed that the investigated refrigerants confirmed that R152a and R134a have approximately the same thermodynamic performances similar to R12 while deviation of R125 and R143a were very large. But the best performance was obtained from the used of R152a in the system. As a result, R152a could be used as a drop-in replacement for R134a in vapour compression refrigeration system. The COP of R152a obtained was higher than those of R12, R125, R134a, R143a. Also, R152a offers the best desirable environmental requirements; zero Ozone Depleting Potential (ODP) and very low Global Warming Potential (GWP).
Authors and Affiliations
Ankit Tiwari
Design and Analysis of T-Shape Dovetail for Improvement in Peripheral Velocities
From the olden days in synchronous machines for attaching mechanically pole windings to the shaft dovetails are used. In general T-shape or Hammered head section is used as type of dovetail. Hammered head dovetail...
ANALYSIS OF ANTIMICROBIAL ACTIVITY SILVER NANOPARTICLE FROM THE BRASSICACEA FAMILY VEGETABLES
Extract of Brassicacea family vegetables is used as reducing agent for the environmentally friendly synthesis of silver nanoparticles at room temperature. The major advantage of using plant extract s for silver nanop...
FACIAL EMOTION RECOGNITION USING GABOR (HAPPY, SAD, ANGER, NEUTRAL MOOD)
The best way to communicate the emotions and intentions is facial expressions. This is powerful because as per the psychological research 55% of the total communicated message is the human facial expression. Therefore de...
Effect of Tensile Properties on Heat Treated 0.38% Medium Carbon Steel
The experiment was conducted using 0.38% carbon in steel it was quenched in oil after austenizing and then tempered from 250oC. The experiment was conducted it was hardened at 900oC followed by tempering. The steel exh...
To Estimate the Cooling Load of a Desire Space with help of C Programming
Cooling load of a desire space is the rate of heat which must be removed from the space to maintain at a specific space air temperature and moisture content. This work provides a procedure for preparing calculatio...