NEW TUNNEL BASED METHOD OF SENSITIVITY MATRIX CALCULATION FOR 3D CAPACITANCE TOMOGRAPHY IMAGE RECONSTRUCTION

Abstract

The sensitivity matrix is main part of the image reconstruction process for 3D ECT imaging and strictly decides about the its final quality. Common sensitivity determination methods mostly provide acceptable results and additionally allow to perform the recalculation of the sensitivities according to the changing permittivity distribution. In this paper authors introduce the crucial modification of the sensitivity determination process based on the electric field distribution analysis. The designed new tunnel based algorithm follows the surfaces constructed along the electric field lines. In the paper the results of the image reconstruction experiments will be shown and the better accuracy of the new method will be proved.

Authors and Affiliations

Radosław Wajman

Keywords

Related Articles

INVARIANT PIEZORESONANCE DEVICES BASED ON ADAPTIVE MULTIFREQUENCY SYSTEMS WITH A PREDICTIVE STANDARD

The paper presents conceptual provisions for the construction of invariant multi-frequency piezoelectric resonance devices with a predictive reference model. The law of the optimal control of the system in real time is f...

POTENCJALNE MOŻLIWOŚCI WYTWÓRCZE FARM WIATROWYCH ZLOKALIZOWANYCH NA TERENIE WOJEWÓDZTWA LUBELSKIEGO

W artykule dokonano oceny możliwości wytwórczych farm wiatrowych mających powstać na terenie województwa lubelskiego, w oparciu o przebiegi prędkości wiatru z lat 2006, 2007, 2008 uzyskane z atlasu wiatru Anemos®. Otrzy...

ALTERNATIVE TERMINATION CRITERION FOR K-SPECIFIED CRISP DATA CLUSTERING ALGORITHMS

In this paper the analysis of k-specified (namely k-means) crisp data partitioning pre-clustering algorithm’s termination criterion performance is described. The results have been analyzed using the clustering validity i...

ANALIZA CHARAKTERYSTYK KORELACYJNYCH I SPEKTRALNYCH SYGNAŁÓW FRAKTALNYCH O STRUKTURZE GRZEBIENIOWEJ

W pracy przedstawiono teoretyczne i eksperymentalne badania widm sygnałów fraktalnych o strukturze grzebieniowej dla różnych wartości ich współczynnika generowania, a także przeprowadzono analizę charakterystyk auto...

LEVEL SET METHODS IN MEDICAL IMAGE PROCESSING

In this paper two image processing methods for use in medical image processing based on the level set method, the Chan-Vese and the distance regulated method are described. The theoretical basics are described and the me...