Open reduction and internal fixation in proximal humerus fractures by proximal humerus locking plate: A study of 60 cases

Journal Title: International Journal of Orthopaedics Sciences - Year 2018, Vol 4, Issue 4

Abstract

Introduction: With respect to approach of proximal humerus fractures there has been a wide variation in optimum modality of treatment ranging from conservative treatment to total and reverse shoulder arthroplasty. We have evaluated the outcome of efficacy of proximal humerus locking plate in displaced proximal humerus fractures. Methods: A total of 60 patients with displaced proximal humerus fractures were included in the study after careful inclusion and exclusion criteria. All fractures were fixed with proximal humerus locking plate and patients were followed up at regular intervals. Final evaluation was done based on Constant and Murley shoulder scoring system. Results: According to Constant and Murley shoulder scoring system there were excellent results in 56.66% cases, good in 18.66%, fair in 13.33% and poor in 11.66% cases. There was no incidence of superficial or deep infection. There were 3 cases of AVN, 4 cases of varus collapse and 2 cases each of implant failure and non-union. Conclusion: Proximal humerus locking plate provides better fixation in proximal humerus fractures particularly in elderly and osteoporotic patients. Calcar screw placement is vital for prevention of varus collapse of fracture.

Authors and Affiliations

Dr. Vikas Patel, Dr. Mukesh Dwivedi

Keywords

Related Articles

Surgical management of compound fracture tibia using an unreamed interlocking nail

Background and Objectives: With increasing number of vehicles on the roads in India, complex trauma cases caused by traffic accidents have increased progressively. Fracture Tibia are among the commonest fractures sustain...

Functional outcome after surgical fixation of middle third clavicular fractures by titanium elastic nailing system (TENS): A prospective study

This study is based on the technique of minimally-invasive osteosynthesis using Titanium elastic nails (TENS) in OTA Type a midclavicular fractures with displacement or shortening more than 2 cm. The aim of the study was...

A clinical study of surgical management of diaphyseal fractures of shaft of femur in children and adolescents using flexible nails

Aim and Objective: In this study 20 patients, aged 5 to 16 years, with fracture shaft of the femur were treated with retrograde flexible intramedullary nailing at Bapuji Hospital and Chigateri General Hospital, attached...

Comparative study for efficacy of autologous growth factor rich plasma (GFRP) versus combination of low molecular weight hyaluronic acid and autologous growth factor rich plasma (GFRP) in bilateral osteoarthritis knee (Grade 1, Grade 2 according to kellgren-lawrence grading system)

Osteoarthritis knee in initial stages can be managed conservatively by various methods, here we did comparative study between intraarticular GFRP injection vs combination of low molecular weight hyaluronic acid & GFRP in...

Management of giant cell tumor of lower third tibia with curettage and reconstruction by cementation and locking plate: A case report

Introduction: Giant cell tumour of bones is an unusual neoplasm that accounts for 4% of all primary tumours of bone, and it represents about 10% of malignant primary bone tumours with its different grades from borderline...

Download PDF file
  • EP ID EP487745
  • DOI 10.22271/ortho.2018.v4.i4b.17
  • Views 114
  • Downloads 0

How To Cite

Dr. Vikas Patel, Dr. Mukesh Dwivedi (2018). Open reduction and internal fixation in proximal humerus fractures by proximal humerus locking plate: A study of 60 cases. International Journal of Orthopaedics Sciences, 4(4), 78-83. https://europub.co.uk./articles/-A-487745