Optimal Operation Control of Composite Ground Source Heat Pump System

Journal Title: Power Engineering and Engineering Thermophysics - Year 2022, Vol 1, Issue 1

Abstract

During the operation of the ground source heat pump (GSHP) system, the operations of the chiller system should be controlled by adjusting the difference between water temperature and wet bulb temperature. Therefore, it is important to consider the control strategy for the switch time (ST) and wet bulb temperature difference (WBTD) of the chiller system. This paper sets up two control strategies, namely, the strategy to control the ST of system operations, and the strategy to control the WBTD. Then, theoretical modeling was carried out to compare the system energy consumption and borehole wall temperature under different strategies. The modeling results were referred to optimize the control strategy for composite GSHP systems. It was found that, under the ST control strategy, the best wet bulb temperature is 2℃, and the best chiller operation hours are 3h; under the WBTD control strategy, the best wet bulb temperature is 3.5℃, and the best WBTD is 1.5℃. In addition, the ST control strategy is superior to the WBTD control strategy, in terms of system energy consumption, borehole wall temperature and initial investment.

Authors and Affiliations

Liang Wang, Shudan Deng

Keywords

Related Articles

Numerical Analysis of Heat Transfer Enhancement Using Fe3O4 Nanofluid Under Variable Magnetic Fields

This study conducts a numerical investigation into the heat transfer enhancement of Fe3O4-distilled water nanofluid within a magnetically influenced environment. The research is centered on the analysis of the impact of...

Measuring Temperatures Generated by Air Plasma Technology

The atmospheric pressure air plasma technology is based on the general principle of transforming the air into an ideal conductor of plasma energy thanks to the application of an electric potential difference able to ioni...

Influence of Cooling and Lubrication Parameters on Robot Bone Grinding Temperature and Prediction Modeling

In the process of robot bone grinding, a large amount of heat is generated, which will cause mechanical and thermal damage to bone tissues and nerves. It is necessary to study the influence of cooling and lubrication par...

Magnetic Field Impacts on Nanofluid Flow Towards a Stretching Sheet Embedded in a Porous Medium with Considerations of Variable Viscosity and Convective Boundary Conditions

This investigation elucidates the intertwined effects of magnetic fields and porous media on the flow of nanofluids towards a stretching sheet, contemplating variable viscosity and convective boundary conditions. A nanof...

A Semiconductor-Based Refrigeration System for Cooling of Water: Design, Construction, and Performance Tests

Convectional refrigeration is one of the causes of global warming as carbon dioxide is emitted from its refrigerant to the environment. Semiconductor-based refrigeration is one of the alternative technologies that can lo...

Download PDF file
  • EP ID EP732011
  • DOI https://doi.org/10.56578/peet010107
  • Views 47
  • Downloads 0

How To Cite

Liang Wang, Shudan Deng (2022). Optimal Operation Control of Composite Ground Source Heat Pump System. Power Engineering and Engineering Thermophysics, 1(1), -. https://europub.co.uk./articles/-A-732011