Abstract

This paper deals with Dynamic Voltage Restorer (DVR) allocation in radial distribution systems by injecting series voltage. The DVR is used to inject both real and reactive powers into the system for voltage profile improvement and active and reactive power loss minimization. The objective of this paper is to identify the optimal location and series voltage of DVR using Particle Swarm Optimization (PSO) algorithm. The proposed method is tested on standard IEEE 33-bus system and the results are presented.

Authors and Affiliations

A. V. Sudhakara Reddy, Dr. M. Damodar Reddy, N. Vinoda

Keywords

Related Articles

Comparison of Max100, SWARA and Pairwise Weight Elicitation Methods

Decision making is used in every part of life and realised by each action taken. The presence of correct and satisfactory solution to problems is very important for person, institution and organizations. Multiple Criteri...

Comparative Study of Design of Industrial Warehouse Using CSB, PEB and Tubular Sections

This Paper provides the comparative study of Conventional steel building (CSB), Pre Engineered Building(PEB) and Tubular Structure. The design is made as per IS 800-2007. Dead load, Live load and wind load calculation is...

Creation and Deployment of Virtual Machine on Cloud

The desire to run multiple operating systems was the initial motive for virtual machines, so as to allow timesharing among several single-tasking operating systems. In some respects, a system virtual machine can be consi...

Simmulation of Rough Rock Joints under Shear Stress

nature that comprises intact rock units separated by discontinuities, e.g. joints, faults and bedding planes. The characteristics of rock joints have major influences on the rock mass behavior and the consequent failure...

An Empirical Method For Determination Of Kinetic Models And Kinetic Parameters Associated To Thermo-OxidativeDegradation Of Recycled Polypropylene (PP)

The kinetics of thermo-oxidative degradation of polypropylene recycled (PP rec.) was investigated using thermogravimetric (TG) analysis in air atmosphere. An empirical methodology was developed, and it is the result of i...

Download PDF file
  • EP ID EP390274
  • DOI 10.9790/9622- 0703012933.
  • Views 138
  • Downloads 0

How To Cite

A. V. Sudhakara Reddy, Dr. M. Damodar Reddy, N. Vinoda (2017). Optimal Placement of Dynamic Voltage Restorer in Distribution Systems for Voltage Improvement Using Particle Swarm Optimization. International Journal of engineering Research and Applications, 7(3), 29-33. https://europub.co.uk./articles/-A-390274