Optimization of Gas Dynamical Subsystem of Transducers for Measurement of Gas Flow Temperature
Journal Title: Energy Engineering and Control Systems - Year 2016, Vol 2, Issue 2
Abstract
The main types of errors which occur while measuring the temperature of gas flows, including flows of fuels, are determined by the conditions of thermal balance at the interaction of the sensor of the temperature transducer (TT) with the gas flow via convection, radiation and conduction. The limited TT capacity to track flow temperature variation should also be taken into consideration. For high gas flow speeds (over 50 m/s), another type of error (the so-called speed error) arises from the transformation of part of kinetic energy of the flow into thermal energy. A comprehensive analytical study of the combined influence of all the major factors on the total error of gas flow temperature measurement with a particular TT is actually impracticable, since some relationships describing the character of influence of this or that factor can be obtained only by experiment. Therefore, in practice, each error type is analysed separately, assuming that no other types of error occur, and the total error of measurement is regarded as superposition of separate error types. For convenience of analysis, TT is represented as a combination of separate units, each with its own components of the error. TT for gas flow temperature measurements appears as three units, such as gas dynamic, thermal and electrical, connected in series. The gas dynamic subsystem transforms the thermodynamic temperature T(τ) of the gas flow at the TT input into the deceleration temperature ТПТ(τ) at the temperature sensor input and is characterized by the speed error. The defining characteristic of the gas dynamic subsystem is the TT recovery factor, which is why the paper discusses the methods and means of ensuring the constancy of the recovery factor.
Authors and Affiliations
Vasyl Fedynets, Ihor Vasylkivskyi, Yaroslav Yusyk
Reduction of Hydrodynamic Flow Measurement Error of Chordal Ultrasonic Flowmeter
In this work, ways of reducing the hydrodynamic flow measurement error of chordal ultrasonic flowmeter for the distributed location schemes of their acoustic paths are investigated. The method of calculating optimal loca...
High-Speed Computer Simulation of Electrical Circuits
The well-known numerical-analytic method based on zeroes/poles matching (as z-transform realization) of equivalent transfer function or complex impedance (conductivity) in Laplace domain was proposed for high-speed compu...
Influence of Type of Solar Modules Anchorages on Power of Solar Power Station
Electricity generation through solar power plants is one of the ways to Ukraine's energy independence. The amount of electricity generated by a solar power plant depends on the intensity of the solar radiation entering o...
Simplified Method for Calculation of the Joule–Thomson Coefficient at Natural Gas Flowrate Measurement
This work deals with measurement of natural gas flowrate and volume by means of pressure differential devices. The existing methods for calculation of Joule-Thomson coefficient to be applied in pressure differential flow...
Method of Selecting the Speed of Jack Pump Driving Motor Based on Reservoir Flow Rate
The sucker-rod oil pumping unit productivity is influenced by lots of factors, including the operation mode of the jack pump electric drive system. Settings of the electric drive system affect the system’s energy indicat...