Outcome of AO Type C Fractures Distal Radius treated with Volar Locking Plates in a Tertiary care center Lahore
Journal Title: Journal of Pakistan Orthopaedic Association - Year 2020, Vol 32, Issue 01
Abstract
Objective: To determine the clinical and radiological outcome of AO Type C fracture distal radius treated with 2.4mm Titanium volar locking plates. Methods: This descriptive study was conducted in Department of Hand and Upper limb Surgery(HULS) Combined Military Hospital(CMH) Lahore Pakistan from 23rd January 2016 to 4th January 2019.All adults patients of either gender with distal radius fractures(Type C) fulfilling the inclusion criteria were treated with 2.4mm volar locking plates. Post operative flexion and extension of the wrist was measured with goniometer and grip strength with a weighing scale. Radiological outcome was determined by comparing pre operative and post operative radial height, radial inclination and volar tilt. P value was calculated for net improvement of radiological outcome and < 0.05 was considered significant. Results: The total number of patients in our study were 52.Mean age of the patients were 40.26 ± 12.7 years(range 18 to 69 years).Male patients were 39(75%) and female 13(25%).Right radius was fractured in 28(53.8%) patients and left in 24(46.1%).AO type C2 fracture was noted in 24(46.1%),C1 in 19(36.5%) and C3 in 9(17.3%) patients. Post operative mean wrist flexion was 78°±7 (range 62° to 80°) and extension 68°±4 (range 60° to 75°)at last follow up. The grip strength was excellent in 22(42.3%), good in 18(34.6%) and average in 12(23%).The mean value of pre operative Radial Height(RH) was improved from5.35±3.32 to 11.42±0.800, Radial Inclination(RI) from 13.83±3.71 to 21.09±0.793 degrees, and Volar Tilt(VT) from 5.43±11.9 to11.22±0.951 degrees. The net improvement in RH, RI and VT was 6.11 ± 2.77, 7.26 ± 2.89 and 15.65 ± 14.26 (P > 0.05).No major complication was documented in our study. Conclusion: Titanium volar locking plates produced excellent functional and radiological outcome in patients with intra articular fractures of the distal radius. We therefore, recommend 2.4mm Titanium volar locking plate as implant of choice to treat Type C fractures.
Authors and Affiliations
Karam Rasool Basra,1Khalid Masood,2Saeed Ahmad,3Khalid ZulifiqarQureshi,4Belal Sadaat,5Hafiz MuhammadKashif Shafi. 6
Radiological Outcome of Shelf Osteotomy in Legg Calve Perthes Disease.
Background: Management of Perthes disease has many controversies. The main goal of treatment is to recover the femoral head in normal shape and to reduce pain and stiffness, to improve range of motion, prevent extrusion...
Assessment of Instability in Degenerative Lumbar Spondylolisthesis using the Standing and Supine Lateral Radiographs.
Objective: To compare the percentage of slip difference using the standing and supine lateral radiographs in symptomatic degenerative lumbar Spondylolisthesis. Methods: This descriptive study was conducted in departme...
A Comparison of Radiological Outcome of Open Reduction in Unilateral VS Bilateral DDH
Objective: The purpose of current study is the comparison of the radiological outcome of open reduction in children with unilateral vs bilateral DDH following staged surgery. Methods: In current study, the medical rec...
Early Outcome of Single Level Lumbar Discectomy in Patients with Prolapsed Intervertebral Disc
discectomy in patients with prolapsed intervertebral disc. Methods: This descriptive study was conducted from 3rd January 2018 to 23rd January 2020 in Orthopaedics and Spine Department Khyber Teaching Hospital Peshawa...
Posterior Stabilized Total Knee Arthroplasty without Patellar Resurfacing.
Introduction: Total Knee arthroplasty remains the most commonly performed surgical procedure for the management of knee osteoarthritis when conservative management fails. Apart from pain relief, improved range of motion...