Outcome of AO Type C Fractures Distal Radius treated with Volar Locking Plates in a Tertiary care center Lahore
Journal Title: Journal of Pakistan Orthopaedic Association - Year 2020, Vol 32, Issue 01
Abstract
Objective: To determine the clinical and radiological outcome of AO Type C fracture distal radius treated with 2.4mm Titanium volar locking plates. Methods: This descriptive study was conducted in Department of Hand and Upper limb Surgery(HULS) Combined Military Hospital(CMH) Lahore Pakistan from 23rd January 2016 to 4th January 2019.All adults patients of either gender with distal radius fractures(Type C) fulfilling the inclusion criteria were treated with 2.4mm volar locking plates. Post operative flexion and extension of the wrist was measured with goniometer and grip strength with a weighing scale. Radiological outcome was determined by comparing pre operative and post operative radial height, radial inclination and volar tilt. P value was calculated for net improvement of radiological outcome and < 0.05 was considered significant. Results: The total number of patients in our study were 52.Mean age of the patients were 40.26 ± 12.7 years(range 18 to 69 years).Male patients were 39(75%) and female 13(25%).Right radius was fractured in 28(53.8%) patients and left in 24(46.1%).AO type C2 fracture was noted in 24(46.1%),C1 in 19(36.5%) and C3 in 9(17.3%) patients. Post operative mean wrist flexion was 78°±7 (range 62° to 80°) and extension 68°±4 (range 60° to 75°)at last follow up. The grip strength was excellent in 22(42.3%), good in 18(34.6%) and average in 12(23%).The mean value of pre operative Radial Height(RH) was improved from5.35±3.32 to 11.42±0.800, Radial Inclination(RI) from 13.83±3.71 to 21.09±0.793 degrees, and Volar Tilt(VT) from 5.43±11.9 to11.22±0.951 degrees. The net improvement in RH, RI and VT was 6.11 ± 2.77, 7.26 ± 2.89 and 15.65 ± 14.26 (P > 0.05).No major complication was documented in our study. Conclusion: Titanium volar locking plates produced excellent functional and radiological outcome in patients with intra articular fractures of the distal radius. We therefore, recommend 2.4mm Titanium volar locking plate as implant of choice to treat Type C fractures.
Authors and Affiliations
Karam Rasool Basra,1Khalid Masood,2Saeed Ahmad,3Khalid ZulifiqarQureshi,4Belal Sadaat,5Hafiz MuhammadKashif Shafi. 6
Comparison of Incidence of Low Back Pain in Women with Normal Vaginal Delivery and Cesarean Section
Objective: To compare the incidence of low back pain between women who underwent caesarean section and those had normal vaginal delivery. Methods: This comparative study was conducted in Dow university hospital from J...
Intra-articular Corticosteroid with Physiotherapy Versus Physiotherapy alone for the Treatment of Frozen Shoulder: A Randomized Controlled Trial
Objective: To compare the treatment outcome of combination of corticosteroid injection with physiotherapy and physiotherapy alone in patients with adhesive capsulitis in term of shoulder pain and disability index (SPADI)...
Management of Infected Non Union Tibial Shaft by Ilizarov Method
To asses the out come of the management of infected non union of tibial shaft by Ilizarov method. Patients and Methods: This prospective study was conducted at department of orthopedic CMC Larkana and GMMMC Sukkur fro...
Assessment of Bone Mineral Density (BMD) among general population of District Khuzdar, Baluchistan Pakistan
Objective: To determine the frequency of osteoporosis and osteopenia among the general population of District Khuzdar, Baluchistan Pakistan. Methods: This was a cross-sectional study and the data was collected on “Wor...
Complications of Fracture Treatment by Traditional Bonesetters
To find out frequency of different complications in patients that has been managed by traditional bonesetters (TBS). Methods: This study was conducted from 1st October 2013 to 31st March 2014. Total 60 patients who prese...