Outcome of fracture distal radius treated with open reduction internal fixation with volar locking compression plate (A study of 50 cases)

Journal Title: International Journal of Orthopaedics Sciences - Year 2018, Vol 4, Issue 1

Abstract

Introduction: Fractures of the distal radius constitute one of the most common skeletal injuries treated by Orthopaedic surgeons. These injuries account for one sixth of all fractures and represent 17% of all the fractures evaluated in emergency room. The use of strong implant in the form of Fixed Angle Volar Locking Compression Plate theoretically achieves, maintain the reduction and stability in displaced intra-articular & extra-articular distal radius fractures in both the economically productive young age group as well as in the osteoporotic elderly population with less bone stock.Hence, we have decided to study the results of management of distal radius fractures with the open reduction and internal fixation with Volar locking compression plates. Aim: To study the results of operative management of distal radius fractures in terms of functional and radiological outcome, with open reduction and internal fixation with Volar locking compression plates. Materials and Methods: This was a prospective study, where Fifty adult patients with distal radial fractures, treated with a volar locking compression plate using a Modified volar Henry approach(i.e flexor carpi radialis FCR approach), were included in this study. The fracture fragments were analyzed and involvement of radiocarpal and distal radioulnar joints were assessed and classified according to the Frykman’s and AO classification. First follow up of patients was done between tenth to fifteenth post-operative days Subsequent follow ups were done for three months at monthly interval.At each follow up clinical and radiological assessment was done using different parameters.Final assessment of the outcome was done after three months, by MAYO WRIST scoring system. Results and Discussion: In our series, we had 90% excellent, 6% good, 2%, fair and 2% poor result. Patients, who obtained excellent results, had no residual deformities or pain. Range of motion was within the normal functional range. Two patients (4%) had arthritic changes but no other complications. They were operated within 6 days after injury. Radial length, volar tilt and articular step-off were within acceptable limits. They were co-operative to physiotherapy. The results obtained in our series are comparable to other studies undertaken similarly. Conclusion: Use of locked compression plates in distal radius fractures provided good to excellent results with correction and maintenance of distal radius anatomy. By using these plates, joint motions and daily functioning were recovered in a shorter time.

Authors and Affiliations

Dr. Umesh Nagrale, Dr. Sagar Kadam, Dr Ravi Bhanushali, Dr. Prasannaditya mujumdar, Dr. Avik Sarkar, Dr. Irphan Shaikh

Keywords

Related Articles

Comparative study between dynamic hip screw & proximal femoral nail in treatment of intertrochanteric fracture

Intertrochanteric fractures are those occurring in the region extending from the extra capsular basilar neck region to the region along the lesser trochanter. Due to an increasing life span and sedentary lifestyle the in...

Functional outcome of Philos plate fixation in proximal humerus fractures

Background: Conservative treatment for Proximal humeral fractures were common in the past and often had compromised functional results. With the advancement of surgical techniques, proximal humerus fractures are now more...

A case of combined posterolateral corner (PLC) injury and anterior cruciate ligament (ACL) injury treated by arthroscopic reconstruction

The combined injuries involving anterior cruciate ligament and posterolateral corner are the rarest among knee injuries with an incidence of about 9.1% and there is a paucity of literature focussing on its management. He...

The orientation of acetabular component in total hip replacement using transverse acetabular ligament as a guide

Introduction: Acetabular component placement is a crucial determinant in outcomes following total hip arthroplasty. Malalignment predisposes to impingement, increased rate of dislocation, wear of the bearing, osteolysis,...

Is Multimodal pain management the new standard of care in total knee replacement?

Background: Measures for pain management after total knee arthroplasty (TKA) are important for early improvement in the quality of life after operation and early postoperative rehabilitation. This study was conducted to...

Download PDF file
  • EP ID EP485898
  • DOI 10.22271/ortho.2018.v4.i1o.143
  • Views 110
  • Downloads 0

How To Cite

Dr. Umesh Nagrale, Dr. Sagar Kadam, Dr Ravi Bhanushali, Dr. Prasannaditya mujumdar, Dr. Avik Sarkar, Dr. Irphan Shaikh (2018). Outcome of fracture distal radius treated with open reduction internal fixation with volar locking compression plate (A study of 50 cases). International Journal of Orthopaedics Sciences, 4(1), 1003-1011. https://europub.co.uk./articles/-A-485898