OUTCOME OF ISOLATED AVULSION FRACTURES TREATED WITH “SUTURE IN BUTTON” FIXATION TECHNIQUE

Journal Title: GJRA-Global Journal For Research Analysis - Year 2018, Vol 7, Issue 1

Abstract

Backgrounds: Management of Anterior cruciate ligament (ACL) avulsion fractures have been described in literature from closed reduction, to both open and arthroscopically assisted fixation. The Purpose of the study is to evaluate clinical and radiological outcomes of new technique of arthroscopic “suture on button” fixation in treating tibial eminence fracture. Methods: This is retrospective study includes 10 patients with ACL avulsion fractures between 2012 and 2015. All patient underwent arthroscopic “suture on button” fixation by the single orthopedic surgeon. The inclusion criteria were a displaced ACL avulsion fracture (Meyer and McKeever Types III and IV), with a minimum follow-up of 18 months. A preoperative MRI was done in all patient to confirm the fracture. Lysholm and IKDC score was used clinical assessment. Results: Clinical assessment none of the patient had complains of Instability. Range of motion measurement showed a mean extension deficit of 2° (0–3) and a mean flexion deficit of 4° (2–6) when compared with the unaffected knee. The average Lysholm knee score was 97 (96–100). Post-operative radiograph in all the patients showed reduction of fracture fragement/s. Radiographic union was achieved in all the patients at 3 months postoperative. Conclusion: The results of the study showed arthroscopic “suture on button” fixation procedure results in good outcome for treatment of ACL avulsion fractures.

Authors and Affiliations

Dr. Rajat Jangir, Dr. Mohit Kumar, Dr. Ravi Mittal

Keywords

Related Articles

Marine Mollusk Fauna of Kastamonu and Sinop Provinces: A Compiled list of Black Sea Mollusks of Turkey

The study was carried out to determine Mollusca fauna of Kastamonu and Sinop coasts. A seasonal sampling procedure was performed in the area from a variety of biotops in 0-0.5 and 5m depths at 4 stations between July 200...

Mobile phones of Health care workers: Friend or Foe

Mobile phones can act as a reservoir of a wide variety of bacterial species, many of which have the potential to be pathogenic. A cross sectional study was carried out in two health facilities in the southern part of Nig...

DETERMINANTS OF THE RETURN ON EQUITY RATIO (ROE) ON TEXTILE COMPANIES IN TAMILNADU

The purpose of this article is to present the possibilities of analyzing popular among investors ratio of ROE and identification the determinants of its growth or decline. Traditionally, according to the DuPont formula t...

COMPARISON OF PROPOFOL, ETOMIDATE AND PROPOFOL-ETOMIDATE COMBINATION AS INDUCTION AGENT ON HAEMODYNAMIC PARAMETRES DURING ENDOTRACHEAL INTUBATION IN PATIENTS UNDERGOING LAPAROSCOPIC CHOLECYSTECTOMY

Background: Endotracheal intubation during general anaesthesia has been associated with change in haemodynamic parameters such as pulse rate and blood pressure. In this study we have compared propofol, etomidate and prop...

FETO-MATERNAL OUTCOME IN SINGLETON PREGNANCIES WITH POLYHYDRAMNIOS: A CASE CONTROL STUDY

Objectives - To study the fetal and maternal outcome, in pregnancies complicated by polyhydramnios with that of pregnancies having normal 􀃸uid volume. Maternal and Methods This prospective case control study was conducte...

Download PDF file
  • EP ID EP457247
  • DOI -
  • Views 112
  • Downloads 0

How To Cite

Dr. Rajat Jangir, Dr. Mohit Kumar, Dr. Ravi Mittal (2018). OUTCOME OF ISOLATED AVULSION FRACTURES TREATED WITH “SUTURE IN BUTTON” FIXATION TECHNIQUE. GJRA-Global Journal For Research Analysis, 7(1), 34-36. https://europub.co.uk./articles/-A-457247