Pacemaker syndrome during temporary epicardiac pacing, after coronary artery bypass grafting: case report and review of the literature
Journal Title: Ελληνικό ηλεκτρονικό Περιοδικό Περιεγχειρητικής Ιατρικής - Year 2017, Vol 16, Issue 0
Abstract
The deficiency of the natural heart pacemaker, the conduction disturbances and the appearance of arrhythmias are common complications after cardiac surgery. Placement of epicardiac electrodes (ventricular, atrial, or both) during cardiac surgery remains common practice, even though few patients will actually need some kind of temporary epicardiac pacing for various periods of time. Temporary epicardiac pacing may be ventricular, atrial or atrioventricular, depending on the specific features of each patient and it aims at preserving the cardiac rhythm, securing the desired heart rate and achieving an acceptable cardiac output. Temporary epicardiac pacing is not without danger, since, under specific circumstances, it may have a negative impact on the hemodynamics of the patient, to the point of circulatory collapse. It may also cause ventricular tachycardia (R on T phenomenon) and cardiac arrhythmias (if pacing is not synchronized to the heart’s natural pacemaker). Ventricular Pacing and Sensing (VVI) is accomplished by the placement of electrodes only on the ventricles, which a priori means a certain degree of hemodynamic compromise, due to the loss of atrial contribution in preserving cardiac output. In certain occasions, this impact may be even more significant. This case report concerns a patient who underwent Coronary Artery Bypass Grafting (CABG) and after placement of the electrodes of temporary epicardiac ventricular pacing he presented significant decrease in systemic arterial pressure and the appearance of cannon A waves on central venous pressure (CVP) tracing every time the pacemaker was triggered. These phenomena, which receded after the disconnection of the pacemaker, consists a case of Pacemaker Syndrome.This problem was solved by adjusting the pacemaker’s frequency at a rate lower than that of the patient’s natural pacemaker.
Authors and Affiliations
Konstantinos Lolakos, Fotini Veroniki, Maria Kyparissa, Barbara Fyntanidou, Eirini Papapostolou, Polychronis Antonitsis, Chrysa Provitsaki, Vasilios Grosomanidis
Fluid management in obstetric anesthesia
Current evidence suggests that the combination of fluid administration and vasoconstrictive medications should be the main strategy for prevention and management of hypotension accompanying neuraxial anesthesia procedure...
Anesthetic management of a patient with Myasthenia Gravis for abdominal surgery
This case report focuses on the anesthetic management of a patient with Myasthenia Gravis who underwent left-sided colectomy, due to the presence of a tumor on the left colic (splenic) flexure. Myasthenia gravis is a chr...
Fatal bacteremia caused by Pantoea agglomerans in a critically ill patient.
We present a case report concerning fatal bacteremia caused by Pantoeaagglomerans in a critically ill patient
Perioperative Haemostaticmonitoring: older vs. newer concepts and techniques
Clinical management of acute severe bleeding in the perioperative setting is one of the major challenges for an anesthetic team. The dynamic nature of bleeding calls for rapid diagnosis and immediate interventions. Traum...
A rare case of late presentation of infantile hypertrophic pyloric stenosis in a 5-year old child
The case describes a late presentation of Infantile Hypertophic Pyloric Stenosis in a 5 year old boy, and its management.