Parametric Study and Analysis of Varying the Condenser Pressure in Thermal Power Plant

Abstract

In this study, the energy and exergy analysis of an ideal Rankin cycle with reheat is presented. The primary objectives of this paper are to analyze the system components separately and to identify and quantify the sites having largest energy and exergy losses at cycle. In addition, the effect of varying the condenser pressure on this analysis will also be presented. The performance of the plant was estimated by a component-wise modeling and a detailed break-up of energy and exergy losses for the considered plant has been presented. Energy losses mainly occurred in the condenser where 2126KW is lost to the environment while nothing was lost from the boiler system because it assumed adiabatic. The percentage ratio of the exergy destruction to the total exergy destruction was found to be maximum in the boiler system 86.27% and then condenser and stack gas 13.73%. In addition, the calculated thermal efficiency was 38.39 % while the exergy efficiency of the power cycle was 45.85%. The boiler is the major source of irreversibilities. For improvement the power plant efficiency the effect condenser pressure has been studied.

Authors and Affiliations

J. Soundhar, M. Thambi Durai, R. Vijay, M. Siva

Keywords

Related Articles

View Independent Drowsy Behaviour and Tiredness Detection

Automatic identification of driver fatigue, drowsiness and sleepiness has many applications such as vehicle safety, operator safety and accident prevention, automatic monitoring and detection systems. This research pape...

Software Engineering Challenges in Mobile Application Development

Software development of mobile applications involves a dynamic environment with frequently changing technologies, user needs and constraints which requires advanced approaches and methodologies in software engineering....

Fabrication and Characterization of B4Cp Particle Reinforced LM24 Al Alloy Composites

In the present investigation, LM 24 Al alloy/B4Cp composites containing three different weight percentages (1, 2, and 3%) with particle size of 10μmm of boron carbide have been fabricated using a compo casting method. T...

Identify the Deterioration in Pipe by Using Wheel Operated Robot

Nowadays, Robots are used in many industries for various purposes. Inspection is the one of the field in which robot used as the inspector. One application is monitoring the inside of the pipe, Recognizing and solving p...

Comparative Analysis for Least Mean Square and Normalized LMS for Speech Enhancement Application

Adaptive Signal Processing (ASP) is an active research area. Adaptive Filter based speech enhancement technique is now a day’s getting very popular due to wide range of applications like mobile communication, hearing ai...

Download PDF file
  • EP ID EP21468
  • DOI -
  • Views 245
  • Downloads 3

How To Cite

J. Soundhar, M. Thambi Durai, R. Vijay, M. Siva (2015). Parametric Study and Analysis of Varying the Condenser Pressure in Thermal Power Plant. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 3(12), -. https://europub.co.uk./articles/-A-21468