پاتوتايپينگ و بررسي شيوع اشريشياكليهاي بيماريزاي رودهاي در نمونههاي آب ورودي به تصفيهخانههاي شهر تهران
Journal Title: آب و فاضلاب - Year 2016, Vol 27, Issue 5
Abstract
Pathotyping of Escherichia coli Isolated from Inlets to Tehran Water Treatment Plants Water borne infections are of great importance for public health due to the role of water in the transmission of pathogens which cause gastrointestinal diseases. Traditional methods based on culture media commonly used for the identification of E. coli are not only time-consuming but fail to detect certain pathotypes of E. coli as well. To overcome these shortcomings, molecular methods were employed in the present study for the rapid and specific determination of E. coli pathotypes. For this purpose, 978 water samples were collected during the period from September 2012 to September 2013 and 106 E. coli strains were selected using multistep biochemical and molecular screening (tetraplex PCR) method. Virulogenes were determined by designing specific primers and developing efficient protocols. While it was shown that water has a great cabapility for transmiting pathogenic microorganisms, the results revealed that 10 strains contained the est, elt, and eaeA genes; five contained the bfpA gene; four contained the pCVD and ipaH genes; three contained the VT1 and VT2 genes; and finally one starin contained the cnf1 and cnf2 genes. It was also found that molecular methods based on our newly designed primers are sensitive, specific, and rapid protocols for pathotyping of Escherichia coli.
Authors and Affiliations
Maryam Asghari, Abbas Akhavan Sepahi, Seyyed Reza Hosseini Doost
اصلاح سطح کربن فعال گرانوله با روش تصفيه نهايي با هدف نيتراتزدايي از آب آشاميدني
Modification of Granular Activated Carbon with Post-Treatment to Enhance Nitrate Removal from Drinking Water The presence of nitrate in groundwater resources has instigated increasing concerns among both managers and use...
Numerical Kinetic and Hydrodynamic Study of Advanced Oxidation Process for a Dye Degradation in a Fluidized Bed Reactor مطالعه عددي سينتيکي و هيدروديناميکي فرايند اکسايش پيشرفته براي حذف ماده رنگزا در راکتور بسترسيال
Abstract Organic contaminants in industrial wastewater are mostly non-biodegradable, so advanced oxidation processes (AOPs) should be used as a promising alternative for conventional treatment processes. In this investi...
بررسي حذف سورفکتانت آنيوني با استفاده از روش انعقاد و شناورسازي الکتريکي تک قطبي Investigation of Anionic Surfactant Removal Using Unipolar Electro-Flotation and Electro-Coagulation
Abstract Surfactants are considered as chemical combinations with many environmental impacts such as eutrophication, foam generation, and oxygen reduction. This experimental study is conducted to evaluate the removal of...
کاليبراسيون پارامترهاي با اثرات ديناميکي در مدلسازي شبکههاي خطوط لوله با تحليل معکوس جريان گذرا در حوزه فرکانس Calibration of Parameters with Dynamic Effects in Pipe Network Simulation Using the Inverse Transient Analysis in the Frequency Domain
Calibration of Parameters with Dynamic Effects in Pipe Network Simulation Using the Inverse Transient Analysis in the Frequency Domain M. H. Ranginkaman1, A. Haghighi2, H. Mohammad Vali Samani3 1. PhD Student of Civil...
Leak Detection in Viscoelastic Pipeline Using Inverse Transient Analysis نشتيابي در خطوط لوله ويسکوالاستيک با استفاده از حل معکوس جريان گذرا
Abstract Leakage in water transmission systems and distribution networks in addition to waste of water and energy, can cause a declined water quality due to exposure to contaminants at low pressure conditions as well as...